Terminal Blocks / Hydraulic / Outlets 2 Sides / No Inlets (Part Numbers - CAD Download)

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Terminal Blocks/Hydraulic/Outlets 2 Sides/No Inlets:Related Image

TypeMaterialSurface TreatmentMax. Operating Pressure
Pitch (P) StandardPitch (P) Configurable
20 Sq.30 Sq.40 Sq.50 Sq.60 Sq.70 Sq.30 Sq.40 Sq.50 Sq.60 Sq.
BTLSBBTLSBTLSKBTLSFLBTLSFLKBTLLBTLSPBTLSKPBTLSFLPBTLSFLKPEN 1.0038 Equiv.Trivalent Chromate20.6MPa≈210kgf/cm2 or less
-BTLSMBTLSMKBTLSFLMBTLSFLKM-BTLSMPBTLSMKP--Electroless Nickel Plating
BTLSBRBTLSRBTLSRKBTLSFLR--BTLSRPBTLSRKP--EN 1.4301 Equiv.-
-BTLSS--------EN 1.4401 Equiv.
-BTLSC--------Brass1MPa≈10kgf/cm2 or less

Specifications

Part Number-Q-R-P
TypeMounting Hole ChangeNumber of Circuits
BTLS
BTLSFLP
BTLA
BTLAP
G-BTLAP

NA
T
ZT
ZT
5
4
4
5
5
-
-
-
-
-
Q3
Q4
Q2
Q2
Q2
-
-
-
-
-
R2
R3
R1
R2
R2

-

-
-

P50

P50
P50




(G Thread)
Part NumberRc (PT), NPT SelectionPitch PNumber of PitchesQ, RABEFXYMounting Hole
TypeMounting Hole ChangeNumber of CircuitsQ, RStandardConfigurable 1mm IncrementNTotal Number of ThreadsM
(20 Sq.)NA (Through)


T (Tapped)


ZT (Counterbore Tapped)
11 (1/8)--022020201066M5
Pitch Standard
BTLSB

BTLSBR



22514
326
438
5410
6512
7614
8716
(30 Sq.)11 (1/8)
2 (1/4)
3 (3/8)
1N (NPT1/8)
2N (NPT1/4)
3N (NPT3/8)
--02303020157.57M6
Pitch Standard
BTLS
BTLSM
BTLSR
BTLSS
BTLSC
Pitch Configurable
BTLSP
BTLSMP
BTLSRP

23525~6014
326
438
5410
6512
7614
8716
(40 Sq.)11 (1/8)
2 (1/4)
3 (3/8)
1N (NPT1/8)
2N (NPT1/4)
3N (NPT3/8)
--02404020207.57M6
Pitch Standard
BTLSK
BTLSMK
BTLSRK
Pitch Configurable
BTLSKP
BTLSMKP
BTLSRKP
23525~6014
326
438
5410
6512
7614
8716
(50 Sq.)12 (1/4)
3
(3/8)
4
(1/2)
6
(3/4)
--02505030257.58M8
Pitch Standard
BTLSFL
BTLSFLM

BTLSFLR
Pitch Configurable
BTLSFLP

26035~6014
326
438
5410
6512
(60 Sq.)12 (1/4)
3
(3/8)
4
(1/2)
6
(3/4)
--02606030307.58M8
Pitch Standard
BTLSFLK

BTLSFLKM
Pitch Configurable
BTLSFLKP

26035~6014
326
438
5410
6512
(70 Sq.)16 (3/4)
8 (1)
--0270704035109M8
Pitch Standard
BTLL
26014
326
438
By inserting "G-" before part number, the thread type can be changed to the G (PF) Thread as part of ordering. (Ex.: G-BTLS) For ordering, see the Ordering Example.
For Q and R, specify 1, 2, 3, 4, 6, 8, 1N, 2N, or 3N indicated before ( ). Single Circuit is not available for Pitch Configurable Type. SUS316 or Brass is for up to 6 connections.
Specify the pitch taking into consideration the necessary dimensions for fitting the couplings. Each 6 and 8 Circuit Type has an additional mounting hole at the midpoint of the overall length. 7 Circuit Type has an additional mounting hole at each midpoint of the 2 - 3 port pitch, and 5 - 6 port pitch from the left to the right. (Except 20 Sq.)
For Block Square □30 Type, when 3/8 is selected for Q and R, tapered male threads may interfere with each other. Select Block Square □40 Type instead.
For Block Square □50 Type, when 3/4 is selected for Q and R, tapered male threads may interfere with each other. Select Block Square □60 Type instead.

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
BTLSMKP2-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP2-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP2-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP2-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKP3-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP3-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP3-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP3-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKP4-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP4-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP4-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP4-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKP5-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP5-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP5-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP5-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKP6-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP6-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP6-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP6-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKP7-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP7-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP7-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP7-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKP8-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP8-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKP8-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKP8-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA2-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA2-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA2-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA2-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA3-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA3-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA3-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA3-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA4-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA4-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA4-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA4-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA5-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA5-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA5-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA5-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA6-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA6-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA6-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA6-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA7-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA7-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA7-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA7-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA8-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA8-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPNA8-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPNA8-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
BTLSMKPT2-[Q1N,​Q2N,​Q3N]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPT2-[Q1N,​Q2N,​Q3N]-R[1,​2,​3]-P[25-60/1]
BTLSMKPT2-Q[1,​2,​3]-[R1N,​R2N,​R3N]-P[25-60/1]
BTLSMKPT2-Q[1,​2,​3]-R[1,​2,​3]-P[25-60/1]
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
RoHSMaterial Surface Treatment Block Size
(mm)
Number of Circuits
(Circuits)
Thread Size / Type Mounting Hole Change Pitch P
(mm)
Pitch Standard / Configurable Application Drawing Q Part Thread Dia. NPT Selection [Q] Drawing R Part Thread Dia. NPT Selection [R] Select a value for PT/PF Thread Dia. on Q (in Drawing). [Q] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1) Select a value for PT/PF Thread Dia. on R (in Drawing). [R] 1(1/8) 2(1/4) 3(3/8) 4(1/2) 6(3/4) 8(1)

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}Not Specified (Counterbore)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 403Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 404Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 405Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 406Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 407Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 408Standard Thread {PT, m (Coarse) Thread}NA (Through)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}T (Tapped)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]--

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}T (Tapped)25 ~ 60Configurable TypeFor hydraulic / Water Pressure1/4 [Q2N] / 1/8 [Q1N] / 3/8 [Q3N]--1 ~ 3

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}T (Tapped)25 ~ 60Configurable TypeFor hydraulic / Water Pressure-1/4 [R2N] / 1/8 [R1N] / 3/8 [R3N]1 ~ 3-

-

1 10 Days 10Steel for General StructureElectroless Nickel Plating40 x 402Standard Thread {PT, m (Coarse) Thread}T (Tapped)25 ~ 60Configurable TypeFor hydraulic / Water Pressure--1 ~ 31 ~ 3

Loading...

Basic information

Shape Intlets - None Outlets - Top & Side

Complementary Products

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360