• Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 3:00 21/4/2024 to 0:00 (CET) 22/4/2024. We apologize for the inconvenience.

Safety Door Switch

Safety Door Switch
Blocks the control circuit by directly opening the contact by using the operation key only used to open the protective door of machine tools

[Features]
· Approved by TÜV
· Approved by UL, CSA.
· Direct opening of contact of switch at the time of opening protective cover by using the direct opening operation mechanism (only at NC contact side).
· Approval of EN standard of direct opening operation is shown by mark on the switch.
· Prevents error operation and fake operation by using exclusive operation key.
· A wide temperature range of -40 to+80°C.
· The protective structure of switch box is approved by IP67 (EN60947-5-1).

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
D4BS-1AFS
D4BS-2AFS
D4BS-15FS
D4BS-25FS
D4BS-K1
D4BS-K2
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Detector Shape Force necessary for press side, O.F.
(N)
Movement up to switching, P.T.
(mm)
Maximum stroke T.T
(mm)
Contact type Main Body External Shape Width W
(mm)
Main Body External Shape Height H
(mm)
Main Body External Shape Length H
(mm)
Conduit size Terminal Specification Details Type Mounting Method Direction of Operation Contact format

110.60 €

1 7 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5Pg13.5Ground terminal (with screws)Main BodyFrontSlow action2NC

115.80 €

1 7 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5G1/2Ground terminal (with screws)Main BodyFrontSlow action2NC

107.00 €

1 6 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5Pg13.5Ground terminal (with screws)Main BodyFrontSlow action1NC/1NO

108.90 €

1 7 Days [Other] Key19.6110±523Mutual insulation double-throw40 -0/+141111.5G1/2Ground terminal (with screws)Main BodyFrontSlow action1NC/1NO

9.60 €

10 7 Days -----262078.7--Operation key main bodyHorizontal Mounting--

10.57 €

10 7 Days -----262053.7--Operation key main bodyVertical Mounting--

Loading...

  1. 1

Basic information

Main Body Size Standard Environment Standard / Cold Resistance Operating Temperature Range(°C) -40::80
Acquisition of Standard Approval TUV / UL / GB(CCC) / CQC / CSA / EN Protective Structure IP67 Mechanical Life(x10K times) 100
Operation Frequency of Machine(times/min. or Less) 30 Rated Operating Voltage(V) 100/125 V AC / More than AC300V Rated Current(A) 10
Cable Specifications - Detector element details - Display Light -
Movement After the Operation OT(mm) - Operating Position OP(mm) - Torque necessary for operation, OF(N▪m) -
Rubber material (scraper) - Box shape - Roller Type -

Tech Support