Outline drawing and specifications table

■Without thread coating
TypeSize (A)[M] Material[S] Surface Treatment
SGPPP
6 8 10
JIS-SWCH10RTrivalent Chromate
SGPPP
15 20 32 40 50
EN-JM 1110 Equiv.Hot Zinc Plating
SUPPP
EN 1.4308 Equiv.
■With thread coating
Type[M] Material[S] Surface Treatment
SGCPPEN-JM 1010 Equiv.Hot Zinc Plating
SUCPPEN 1.4308 Equiv.
[!] Heat Resistance Temperature: 150°C

Specification Table

■Without thread coating
Part Number
SGPPP20A
■With thread coating
Part Number
SGCPP20A
■Without thread coating
Part NumberR
(PT)
Square
H
tL
TypeNo.SGPPPSUPPP
SGPPP
SUPPP
6 A1/8771616
8 A1/4981919
10 A3/81292121
15 A1/214102625
20 A3/417112928
25 A119123131
32 A1 1/423133535
40 A1 1/226143636
50 A232154141
* Shape of H: No.6A to 50A = Square
 
■With thread coating
Part NumberR
(PT)
Square
H
tL
TypeNo.SGCPPSUCPP
SGCPP
SUCPP
6 A1/8771616
8 A1/4981919
10 A3/81292121
15 A1/214102625
20 A3/417112928
25 A119123131

Part number list

Number of items
Part number
SGPPP15A

Material

Screw Nominal T1

Applicable Fluid

Surface Treatment

Seal Coating

RoHS?Minimum order quantity
[Steel] SWCH10R Equiv.
1/2B(15A)
Pulsating Water, Static Flow Water / Air / Steam / Gas / Oil
Trivalent Chromate
Not Provided
10
1 pieces
Unit price (excluding VAT)(Unit price including VAT)
Standard shipping days
1.22 €0.96 €
( 1.14 € )
Stock item: 1 working dayAvailable for same-day shipping

More Information

Basic information

[Connection type] Screw (terminal); Connection form: Plug; Material: You can choose from EN 1.4308 Equiv., JIS-SWCH10R, EN-JM 1010 Equiv. or FCMB 275-5.

Outline and specifications

Specifications/Overview

Operating Conditions of Fittings
Fluid StateMax. Operating Pressure Mpa
Steam, Air, Gas, Oil: Up to 300°C1.0
Steam, Air, Oil, Pulsating Water: Up to 200°C1.4
Static Flow Water: Up to 120°C2.0
* Pulsating Water is a stream of water that is generated under steady operating conditions and varies in pressure and flow rate on a cycle basis. (Except for transitional change)
* Static Flow Water is a non-pulsating stream of water.