Configure
  • Stock
  • Effective Sectional Area IN→OUT(mm2)
  • Effective Sectional Area out→EX(mm2)
  • Tube O.D. D(Ø)
  • Type
  • CAD
  • Est. shipping days
    • All
    • Same-day shipping possible
    • Within 5 working days
  • Quick Exhaust Valves / Straight / Open to Air

    Part number:

    Still undefined. 2 possible part numbers found.
    Quantity:

    Outline drawing and specifications table

    EQUS
    ■ Specifications
    Applicable FluidAir
    Operating Pressure Range0.1 to 0.7 MPa
    Pressure Resistance1.35 MPa
    Operating Temp, Range5 to 60°C
    (Non-Freezing)
    Min. Operating Pressure0.05 MPa
    Graphic Symbol
    [M]Material: Polybutylene Terephthalate

    Specification Table

    Part Number
    EQUS4

    ■Quick Exhaust Valves - Straight
     
    Part NumberBLP1P2P3CEffective Cross Sectional Area (mm2)Mass
    (g)
    TypeTube O.D.
    (mm)
    D
    IN > OUTOUT > EX
    EQUS434.6118.4109111.81.83.3
    6371210.4121111.6444.9

    Part number list

    Number of items
    Part number

    Effective Sectional Area IN→OUT

    (mm2)

    Effective Sectional Area out→EX

    (mm2)

    Tube O.D. D

    (Ø)

    RoHS?Minimum order quantity
    1.8
    1.8
    4
    10
    1 pieces
    4
    4
    6
    10
    1 pieces
    Unit price (excluding VAT)(Unit price including VAT)
    Standard shipping days
    8.82 €
    ( 10.50 € )
    Stock item: 1 working dayAvailable for same-day shipping
    9.32 €
    ( 11.09 € )
    5 working days

    More Information

    Basic information

    [Features] This exhaust valve can support high-speed cylinder drive as the air can be discharged quickly.

    Outline and specifications

    Specifications/Overview


    ■ Features
    Applicable to high-speed driving cylinder since air is quickly exhausted.
    For exhaust throttle type, the driving speed of cylinder can be adjusted.
    ■ Precautions
    ·For types with exhaust throttle, exhaust resistance increases due to clogging of the element.
     This may cause the entire system to malfunction.
     In such cases, discontinue the use and replace the valve.
    ·Not applicable as a shuttle valve.