Configure

Refrigerated Air Dryer, Refrigerant R134a (HFC) High Temperature Air Inlet, IDU□E Series

Part number:

Still undefined. 14 possible part numbers found.
Quantity:

Part number list

Number of items

Air Inlet Flow Rate [Distinction]

(l/min)

Air Inlet Flow

(l/min)

Exit Air Atmospheric Pressure Dew Point

(°C)

Air Temperature at the Inlet Port

(°C)

Air Pressure at the Inlet Port Side

(MPa)

Supply Side, Nominal Designation of Piping Thread

Control SideNominal Pipe Threads

Power Supply Voltage

Specifications

Air Compressor Size

Auto drain

Copper Tube Anti-rust Processing

Leakage Circuit Breaker

Operation, Terminal block for abnormal signal takeout

Minimum order quantity
Up to 400
320 ~ 370
10
55
0.7
3/8
3/8
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
2.2 kW
None
None
None
None
1 pieces
Up to 400
320 ~ 370
10
55
0.7
3/8
3/8
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
Medium air pressure specification (Case for auto drain: metal case with level gauge)
2.2 kW
None
None
None
None
1 pieces
Up to 400
320 ~ 370
10
55
0.7
3/8
3/8
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
2.2 kW
With heavy-duty auto drain
None
None
None
1 pieces
Up to 1000
520 ~ 570
10
55
0.7
1/2
1/2
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
Medium air pressure specification (Case for auto drain: metal case with level gauge)
3.7 kW
None
None
None
None
1 pieces
Up to 1000
520 ~ 570
10
55
0.7
1/2
1/2
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
3.7 kW
With heavy-duty auto drain
None
None
None
1 pieces
Up to 1000
750 ~ 820
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
Medium air pressure specification (Case for auto drain: metal case with level gauge)
5.5 kW
None
None
None
None
1 pieces
Up to 1000
750 ~ 820
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
5.5 kW
With heavy-duty auto drain
None
None
None
1 pieces
Up to 2,000
1,100 / 1,200
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
7.5 kW
None
None
None
None
1 pieces
Up to 2,000
1,100 / 1,200
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
Medium air pressure specification (Case for auto drain: metal case with level gauge)
7.5 kW
None
None
None
None
1 pieces
Up to 2,000
1,100 / 1,200
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
7.5 kW
With heavy-duty auto drain
None
None
None
1 pieces
Up to 2,000
1,500 / 1,700
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
Medium air pressure specification (Case for auto drain: metal case with level gauge)
11 kW
None
None
None
None
1 pieces
Up to 2,000
1,500 / 1,700
10
55
0.7
3/4
3/4
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
None
11 kW
With heavy-duty auto drain
None
None
None
1 pieces
Up to 5000
2,600 / 2,800
10
55
0.7
1
1
Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz)
Medium air pressure specification (Case for auto drain: metal case with level gauge)
15 kW
None
None
None
None
1 pieces
Up to 5000
2,600 / 2,800
10
55
0.7
1
1
Single-phase 230 V AC (50 Hz)
None
15 kW
None
None
None
None
1 pieces
Unit price (excluding VAT)(Unit price including VAT)
Standard shipping days
2,111.02 €
( 2,512.11 € )
26 working days
2,436.65 €
( 2,899.61 € )
26 working days
2,382.08 €
( 2,834.68 € )
26 working days
2,821.71 €
( 3,357.83 € )
26 working days
2,767.15 €
( 3,292.91 € )
26 working days
3,458.74 €
( 4,115.90 € )
26 working days
3,404.18 €
( 4,050.97 € )
26 working days
3,477.82 €
( 4,138.61 € )
26 working days
3,803.48 €
( 4,526.14 € )
26 working days
3,748.92 €
( 4,461.21 € )
26 working days
4,319.23 €
( 5,139.88 € )
26 working days
4,264.68 €
( 5,074.97 € )
26 working days
4,651.97 €
( 5,535.84 € )
26 working days
4,326.35 €
( 5,148.36 € )
26 working days

More Information

Basic information

Refrigerated air dryer that protects pneumatic equipment from moisture.
[Features]
· Removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.
· Improved corrosion resistance with the use of stainless-steel heat exchanger.
· High-temperature intake air type.
· IDU-□E-10: Single-phase: 100 V AC (50 Hz), 100/110 V AC (60 Hz).
· IDU-□E-20: Single-phase: 200 V AC (50 Hz), 200/220 V AC (60 Hz).
· IDU-□E-23: Single-phase 230 V AC (50 Hz).

Caution

  • Product images may be representative images only. Please refer to the manufacturer's catalog for shape details.