Electronic Pressure Monitor (Part Numbers)

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
PV8023
PV8060
PY7093
PY7094
PY9920
PY9961
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Number of Inputs and Outputs Parameter Max. Voltage Drop Switching Output AC
(V)
Min. Pressure Cycles Protection Min. Bursting Pressure
(kPa)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Measuring Range
(bar)
Materials Current Consumption
(mA)
Protection Class Measuring Range
(kPa)
Application Conditionally Suitable For Type of Short-Circuit Protection Process Connection Connection Measuring Element Operating Voltage
(V)
IO-Link Resolution Temperature
(K)
Electrical Connection Min. Bursting Pressure
(MPa)
Ambient Temperature
(°C)
Process Connection Sealing Overvoltage Protection Reverse Polarity Protection Permanent Current Rating of Switching Output AC
(mA)
Output Function Medium Temperature
(°C)
Total Number of Outputs Max. Load
(Ω)
Switching Frequency DC
(Hz)
Min. Load Resistance
(Ω)
IO-Link Resolution Pressure
(MPa)
Restrictor Element Integrated Output Signal Short-Circuit Protection Operating Voltage Tolerance
(%)
Switching Cycles (Mechanical) Switching Frequency AC
(Hz)
Nominal Voltage AC
(V)
Communication Interface Tightening Torque
(Nm)
Special Feature Application Media Analogue Input (Current)
(mA)
Overload Protection No Dead Space Min. Insulation Resistance
(MΩ)
Short-Circuit Proof IO-Link Revision Analogue Input (Voltage)
(V)
Measuring Range
(MPa)
Installation Display Materials (Wetted Parts) Transmission Type Min. Bursting Pressure
(bar)
MAWP (for Applications According to CRN)
(mbar)
Type of Pressure

182.78 €

1 4 Days Number of digital outputs: 2--60 million; (at 1.2 times nominal pressure)IP 67; IP 69K-PNP/NPN-0-601.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI< 15III-For industrial applications-pulsedthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5-metallic thin film cell18-30 DC0.2Connector: 1 x M12--40-90FKM (to DIN 3869)-Yes-normally open / normally closed; (parameterisable)-40-902-< 130-0.002YesSwitching signal; IO-Link; (configurable)Yes----IO-Link25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating)-Liquids and gases-Yes-100; (500 V DC)-1.1----stainless steel (1.4305 / 303); 1.4542 (17-4 PH / 630)COM2 (38.4 kBaud)---

187.77 €

1 4 Days Number of digital outputs: 2--60 million; (at 1.2 times nominal pressure)IP 67; IP 69K-PNP/NPN-0-6001.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI< 15III-For industrial applications-pulsedthreaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5-metallic thin film cell18-30 DC0.2Connector: 1 x M12--40-90FKM (to DIN 3869)-Yes-normally open / normally closed; (parameterisable)-40-902-< 130-0.02YesSwitching signal; IO-Link; (configurable)Yes----IO-Link25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating)-Liquids and gases-Yes-100; (500 V DC)-1.1----stainless steel (1.4305 / 303); 1.4542 (17-4 PH / 630)COM2 (38.4 kBaud)---

428.13 €

1 62 Days Number of digital outputs: 2Factory setting-100 millionIP 65; IP 67-PNP/NPN-0-2.5stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC< 35III-For industrial applicationsFor gaseous media the application is limited to max. 25 bar.pulsedthreaded connection G 1/4 internal threadpnpceramic-capacitive pressure measuring cell18-30 DC; (according to EN 50178 SELV/PELV)----25-80--Yes-normally open / normally closed; (parameterisable)-25-802-< 170--No (can be retrofitted)Switching signal; IO-Link; (configurable)Yes-100 million--IO-Link25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating)Gold-plated contactsLiquids and gases-Yes-100; (500 V DC)-1.1---Display unit: 3 x LED, green (bar, psi, MPa)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L); ceramics; FKMCOM2 (38.4 kBaud)---

417.69 €

1 4 Days Number of digital outputs: 2Factory setting-100 millionIP 65; IP 67-PNP/NPN--1-10stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC< 35III-For industrial applications-pulsedthreaded connection G 1/4 internal thread60 msceramic-capacitive pressure measuring cell18-30 DC; (according to EN 50178 SELV/PELV)----25-80--Yes-normally open / normally closed; (parameterisable)-25-802-< 170--No (can be retrofitted)Switching signalYes-100 million---25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating)Gold-plated contactsLiquids and gases-Yes-100; (500 V DC)-----Display unit: 3 x LED, green (bar, psi, MPa)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L); ceramics; FKM----

533.31 €

1 12 Days Number of digital outputs: 1-2100 millionIP 67-Triac-0-400FKM; PA; PBT; PC; stainless steel (1.4301 / 304)< 10II----threaded connection G 1/4 internal thread--85-265 AC-miniature fuse to IEC60127-2 sheet 1; ≤ 5 A; fast acting|Connector: 1 x 1/2"--25-80--No250; ((-70 °C) 1000 (-60 °C) 1500 (-45 °C) 2500 (-20 °C))normally open / normally closed; (parameterisable)-25-801----YesSwitching signal-5-10-< 160< 250-----No-100; (500 V DC)No----Switching status: LED, red
function display: 7-segment LED display
measured values: 7-segment LED display
Display unit: bar; psi; Mpa
stainless steel (1.4305 / 303); ceramics; FKM----

527.27 €

1 12 Days Number of digital outputs: 2-3100 millionIP 67-PNP-0-250stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; EPDM/X< 50III--For gaseous media the application is limited to max. 25 bar.pulsedthreaded connection G 1/4 internal thread--24 AC / 18-55 DC-Connector: 1 x M12; Contacts: gold-plated--20-80-Yes; (< 60 V DC / < 40 V AC)Yes100normally open / normally closed; (parameterisable)-25-802-< 170--No (can be retrofitted)Switching signalYes20-< 170---Gold-plated contactsLiquids and gases---100; (500 V DC)-----Display unit: 3 x LED, green
switching status: 2 x LED, yellow
function display: alphanumeric display, 4-digit
measured values: alphanumeric display, 4-digit
stainless steel (1.4305 / 303); ceramics; FKM----

Loading...

Tech Support