Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Part Number
|
---|
AC1212 |
AC1221 |
AC1226 |
AC1253 |
AC1254 |
AC1256 |
AC1257 |
AC1258 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Overload Performance | Output Voltage AS-I (V) | Derating (W/K) | Input Current (Nominal Voltage 230 V AC / 50 Hz) (A) | Integrated Data Decoupling | Protection | Nominal Voltage DC (V) | Max. Residual Ripple (mV) | Mains Buffering Time (Nominal Voltage 120 V AC / 60 Hz) (ms) | AS-I Certificate | Input Voltage DC (V) | Materials | Protection Class | Switch-On Peak Current (Nominal Voltage 230 V AC / 50 Hz) (A) | Output Current AS-I (A) | Type of Short-Circuit Protection | Power Loss (Nominal Voltage 230 V AC / 50 Hz) (W) | Operating Voltage (V) | Electrical Connection | Switch-On Peak Current (Nominal Voltage 120 V AC / 60 Hz) (A) | Frequency AC (Hz) | Power Loss in Open-Circuit Operation (W) | Ambient Temperature (°C) | Overvoltage Protection | Mains Buffering Time (Nominal Voltage 230 V AC / 50 Hz) (ms) | Power Factor (Nominal Voltage 120 V AC / 60 Hz) | Nominal Frequency AC (Hz) | Inrush Current Limitation | Type of Mounting | Number of Output Circuits | External Input Protection | Short-Circuit Protection | Operating Voltage Tolerance (%) | Power Factor (Nominal Voltage 230 V AC / 50 Hz) | Back Feeding Protection (V) | Output Power (Peak) (W) | Efficiency (Nominal Voltage 230 V AC / 50 Hz) (%) | Power Loss (Nominal Voltage 120 V AC / 60 Hz) (W) | Nominal Voltage AC (V) | Input Current (Nominal Voltage 120 V AC / 60 Hz) (A) | Input Voltage Range AC (V) | Efficiency (Nominal Voltage 120 V AC / 60 Hz) (%) | Output Power (Permanent) (W) | Max. Power-On Delay Time (ms) | Short-Circuit Proof | Dimensions (mm) | Display | Fuse (A) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
802.14 € | 1 | 4 Days | - | 29.5-31.6; (to PELV) | 1 (60-70 °C) | - | Yes | IP 20 | - | 50 | - | 21901 | - | Aluminium | - | - | 4 | - | 30 | - | terminals: -2.5 mm² | - | - | 4 | -10-60 | - | - | - | 47-63 | - | - | 2 | > 10 A | Yes | - | - | - | - | - | - | 110 / 230 | - | 88-132 / 184-264 | - | - | 500 | - | - | Function: 2 x LED, green | 8; (not accessible) | ||
261.94 € | 1 | 3 Days | - | 29.5-31.6 | 2% / K (> 60° C) | - | Yes | IP 20 | - | 50 | - | 91001 | - | PC; ABS | II | - | 1.9 | - | - | - | cage clamps: -1.5 mm² | - | - | - | 0-70 | Yes; (< 34 V) | 90 | - | 47-63 | - | rail; (TH35 (EN 60715); free space for convection cooling 30 mm) | 1 | - | - | 10 | - | - | - | 88 | - | 110 / 230 | - | 100-240 | - | 60 | 380 | Yes | 45 x 90 x 100 | AS-i voltage: LED, green | 10; (external. characteristics B) | ||
417.30 € | 1 | 3 Days | - | 29.5-31.6; (to PELV; NEC Class II) | 2 (60-70 °C) | - | Yes | IP 20 | - | 50 | - | 54401 | - | Aluminium; steel sheet galvanised | - | - | 2.8 | electronically protected | - | - | cage clamps: | - | - | - | -10-70 | Yes; (< 55 V) | - | - | 47-63 | - | - | 1 | > 6 A | Yes | - | - | - | - | - | - | 110 / 230 | - | 85-132 / 184-264 | - | 85 | 100 | - | - | Function: LED, green goes off in case of overload U < 28 V IR addressing LED, red | - | ||
744.60 € | 1 | 4 Days | output current constant | 30.5 | - | - | - | - | - | - | - | 98401 | - | steel sheet | I | - | - | - | - | - | - | - | 47-64 | - | -25-70 | Yes; (< 36 V) | - | - | - | - | rail; (TH35 (EN 60715)) | - | - | - | 15-20 | - | - | 256 | - | - | 400 | - | 380-480 | - | 244 | 90 | Yes | 124 x 62 x 120 | AS-i voltage: LED, green | - | ||
446.71 € | 1 | 4 Days | output current constant | 30.5 | - | - | - | - | - | - | - | 98601 | - | steel sheet | I | - | - | - | - | automatic range selection | - | - | 47-64 | - | -25-70 | Yes; (< 36 V) | - | - | - | - | rail; (TH35 (EN 60715)) | - | - | - | 10 | - | - | 134 | - | - | 110 / 230 | - | 100-120 / 200-240 | - | 122 | 900 | Yes | 124 x 40 x 120 | AS-i voltage: LED, green | - | ||
359.35 € | 1 | 4 Days | output current constant | 30.5; (to PELV; NEC Class II) | 0 (60-70 °C) | 0.86 | Yes | - | - | 50 | 98 | 98701 | - | steel sheet | I | 3 | 2.8 | - | 11.6 | automatic range selection | - | 3 | 47-64 | - | -25-70 | Yes; (< 36 V) | 96 | 0.56 | - | Yes | rail; (TH35 (EN 60715)) | 1 | ≤ B-10 A / ≤ C-6 A | - | 10 | 0.47 | 35 | - | 88 | 12.9 | 110 / 230 | 1.44 | 100-120 / 200-240 | 86.9 | 85 | 900 | Yes | 124 x 40 x 120 | AS-i voltage: LED, green | - | ||
511.57 € | 1 | 4 Days | output current constant | 30.5 | - | - | - | - | 24 | - | - | 98801 | 24 | steel sheet | III | - | - | - | - | - | - | - | - | - | -25-70 | Yes; (< 36 V) | - | - | - | - | rail; (TH35 (EN 60715)) | - | - | - | 25-35 | - | - | 134 | - | - | - | - | - | - | 122 | 650 | Yes | 124 x 40 x 120 | AS-i voltage: LED, green | - | ||
630.05 € | 1 | 4 Days | output current constant | 30.5 | - | - | - | - | - | - | - | 98501 | - | steel sheet | I | - | - | - | - | automatic range selection | - | - | 47-64 | - | -25-70 | Yes; (< 36 V) | - | - | - | - | rail; (TH35 (EN 60715)) | - | - | - | 10 | - | - | 256 | - | - | 110 / 230 | - | 100-120 / 200-240 | - | 244 | 800 | Yes | 124 x 62 x 120 | AS-i voltage: LED, green | - |
Loading...
Parallel Connection of Outputs Possible | No | Series Connection of Outputs Possible | No | Overload Protection | Yes |
---|
Configure
Basic Attributes
Overload Performance
Output Voltage AS-I(V)
Derating(W/K)
Input Current (Nominal Voltage 230 V AC / 50 Hz)(A)
Integrated Data Decoupling
Protection
Nominal Voltage DC(V)
Max. Residual Ripple(mV)
Mains Buffering Time (Nominal Voltage 120 V AC / 60 Hz)(ms)
AS-I Certificate
Input Voltage DC(V)
Materials
Protection Class
Switch-On Peak Current (Nominal Voltage 230 V AC / 50 Hz)(A)
Output Current AS-I(A)
Type of Short-Circuit Protection
Power Loss (Nominal Voltage 230 V AC / 50 Hz)(W)
Operating Voltage(V)
Electrical Connection
Switch-On Peak Current (Nominal Voltage 120 V AC / 60 Hz)(A)
Frequency AC(Hz)
Power Loss in Open-Circuit Operation(W)
Ambient Temperature(°C)
Overvoltage Protection
Mains Buffering Time (Nominal Voltage 230 V AC / 50 Hz)(ms)
Power Factor (Nominal Voltage 120 V AC / 60 Hz)
Nominal Frequency AC(Hz)
Inrush Current Limitation
Type of Mounting
Number of Output Circuits
External Input Protection
Short-Circuit Protection
Operating Voltage Tolerance(%)
Power Factor (Nominal Voltage 230 V AC / 50 Hz)
Back Feeding Protection(V)
Output Power (Peak)(W)
Efficiency (Nominal Voltage 230 V AC / 50 Hz)(%)
Power Loss (Nominal Voltage 120 V AC / 60 Hz)(W)
Nominal Voltage AC(V)
Input Current (Nominal Voltage 120 V AC / 60 Hz)(A)
Input Voltage Range AC(V)
Efficiency (Nominal Voltage 120 V AC / 60 Hz)(%)
Output Power (Permanent)(W)
Max. Power-On Delay Time(ms)
Short-Circuit Proof
Dimensions(mm)
Display
Fuse(A)
Filter by standard shipping days
Optional Attributes