Configure

Pressure sensor, SPAE Series

Pressure sensor, SPAE Series

Click image to view enlarged image

Part number:

Still undefined. 12 possible part numbers found.
Quantity:

Part number list

Number of items
Related

Pneumatic connection

Pressure measuring range initial value

(bar)

Pressure measuring range end value

(bar)

Max. overload pressure

(bar)

Manufacturer part #

Minimum order quantity
Cartridge 10 mm
-1
1
5
8025979
1 pieces
Flange
0
10
15
8001449
1 pieces
QS-3
0
10
15
8001447
1 pieces
QS-4
0
10
15
8001448
1 pieces
Push-in sleeve QS-4
0
10
15
8001445
1 pieces
Push-in sleeve QS-6
0
10
15
8001446
1 pieces
Flange
0
-1
5
8001444
1 pieces
Cartridge 10 mm
0
-1
5
8025978
1 pieces
QS-3
0
-1
5
8001442
1 pieces
QS-4
0
-1
5
8001443
1 pieces
Push-in sleeve QS-4
0
-1
5
8001440
1 pieces
Push-in sleeve QS-6
0
-1
5
8001441
1 pieces
Unit price (excluding VAT)(Unit price including VAT)
Standard shipping days
119.05 €
( 141.67 € )
9 working days
86.32 €
( 102.72 € )
4 working days
88.46 €
( 105.27 € )
4 working days
88.46 €
( 105.27 € )
3 working days
84.18 €
( 100.17 € )
4 working days
84.18 €
( 100.17 € )
4 working days
86.32 €
( 102.72 € )
4 working days
96.08 €
( 114.34 € )
4 working days
88.46 €
( 105.27 € )
4 working days
88.46 €
( 105.27 € )
4 working days
84.18 €
( 100.17 € )
3 working days
84.18 €
( 100.17 € )
4 working days

More Information

Basic information

[Specifications]
・Operating medium: Compressed air as per ISO 8573-1:2010 [7:4:4]
・Corrosion resistance class (CRC): 2 - Moderate corrosion stress
・Protection Rating: IP40

[Features]
・Electronic pressure sensor with piezoresistive pressure measuring cell, integrated signal processing, numeric pressure indicator in percent, operating key and a switching output, PNP/NPN switchable
・Display of minimum and maximum measured value
・All parameters entered can be transferred to other SPAEs (replicating function)
・Communication interface IO-Link
・The extremely small, extremely light, extremely convenient pressure transmitter SPAE monitors the pressure level of filtered compressed air from −1 … 0 and 0 … 10 bar. Ideal for vacuum monitoring with pick & place or for pressure monitoring in pneumatic applications