Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Part Number
|
---|
E3NC-SA21 2M |
E3NC-SA54 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Type | Detection Method | Optical axis arrangement type | Beam Shape | Light Source | Case Material | Amplifier accessory type | Detection distance [classification] (mm) | Reflection type detection method | Operating Environment | Ambient Operating Temperature (°C) | Protective Structure | Head maximum size width (mm) | Head maximum size height (mm) | Head maximum size, depth (mm) | Amplifier function (selectable only when amplified) | Power Supply Voltage (V) | Output Format | Connection Method | Cord Length (m) | Timer | Spot Dia. (mm) | Response time (standard mode) (ms) | Accessories (dedicated reflective plate, etc.) | Laser class | Applicable Sensors | Input/Output | Detection Distance details (mm) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
341.02 € | 1 | 7 Days | [Laser Sensor] Laser Sensor (Amplifier) | [Penetration] Through Beam Type | - | - | - | [Resin] Polycarbonate | Amplifier only | - | - | Standard / Cold Resistance | −25~40 | - | - | - | - | Threshold Automatic Correction / External Input / Response time setting / Power Tuning Function | VDC 10–30 | NPN Output | Integrated Cable Type | 2 | User can select from timer function disabled / OFF-delay / ON-delay / one-shot / ON-OFF delay | - | 10 | - | - | E3NC-SH100/E3NC-SH250 | 2 Output + 1 Input | - | ||
341.02 € | 1 | 3 Days | [Laser Sensor] Laser Sensor (Amplifier) | [Penetration] Through Beam Type | - | - | - | [Resin] Polycarbonate | Amplifier only | - | - | Standard | −25~40 | - | - | - | - | Threshold Automatic Correction / External Input / Response time setting / Power Tuning Function | VDC 10–30 | PNP Output | M8 Connector | - | User can select from timer function disabled / OFF-delay / ON-delay / one-shot / ON-OFF delay | - | 10 | Instruction manual | - | - | 1 Output + 1 Input | - |
Loading...
Head shape | Square shape | Ambient Operating Humidity(%) | 35::85 |
---|
Configure
Basic Attributes
Type
Detection Method
Optical axis arrangement type
Beam Shape
Light Source
Case Material
Detection distance [classification](mm)
Reflection type detection method
Operating Environment
Protective Structure
Head maximum size width(mm)
Head maximum size height(mm)
Head maximum size, depth(mm)
Amplifier function (selectable only when amplified)
Power Supply Voltage(V)
Output Format
Connection Method
Cord Length(m)
Timer
Spot Dia.(mm)
Response time (standard mode)(ms)
Accessories (dedicated reflective plate, etc.)
Laser class
Applicable Sensors
Input/Output
Detection Distance details(mm)
Type
Amplifier accessory type
Filter by CAD data type
Filter by standard shipping days
Optional Attributes