Miniature Safety Limit Switch [D4N] (Part Numbers - CAD Download)

Miniature Safety Limit Switch [D4N]
  • Promotional pricing
  • Volume Discount
Safety Limit Switches compatible to the Popular D4D, Providing a Full Lineup Conforming to International Standards
• Lineup includes three contact models with 2NC/1NO and 3NC in addition to the 1NC/1NO, and 2NC contact models. Models with MBB contacts are available too.
• M12-connector models are available, saving on labor and simplifying maintenance.
• Standardized gold-clad contacts provide high contact reliability. Can be used with both standard loads and microloads.
• Free of lead, cadmium, and hexavalent chrome, reducing the burden on the environment.
• Conforms to EN115 and EN81-1.
• Lineup includes both slow-action and snap-action models with Zb contacts.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
D4N-1A31
D4N-2A31
D4N-4A31
D4N-9B31
D4N-2131
D4N-8131
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Detector Shape Main Body Size Environment Kings of Plunger Type Roller Lever Type Lever Shape Types of Rod Shape Acquisition of Standard Approval Force necessary for press side, O.F.
(N)
Movement up to switching, P.T.
(mm)
Angle up to switching, P.T.
(deg)
Maximum stroke T.T
(mm)
Maximum angle T.T
(deg)
Contact type Types of contact point Mechanical Life
(x10K times)
Operation Frequency of Machine
(times/min. or Less)
Rated Operating Voltage
(V)
Main Body External Shape Width W
(mm)
Main Body External Shape Height H
(mm)
Main Body External Shape Depth D
(mm)
Lever length R
(mm)
Detector element details Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N▪m)
Conduit size Terminal Specification Details Type Outer Diameter
(mm)
Mounting Method Direction of Operation Roller Type Contact format Degree of Protection (NEMA) Type of Control Element Alignment of the Control Element Type of Electric Connection Coating Housing Switching Function Construction Type Housing With Status Indication Forced Opening Number of Contacts as Change-Over Contact Number of Contacts as Normally Closed Contact Number of Contacts as Normally Open Contact Rated Operation Current Ie at AC-15, 230 V
(A)
Number of Safety Auxiliary Contacts Rated Operation Current Ie at AC-15, 125 V
(A)
Rated Operation Current Ie at DC-13, 125 V
(A)
Rated Operation Current Ie at DC-13, 230 V
(A)
Suitable for Safety Functions

24.90 €

1 7 Days Plunger TypeSmall SizeStandard[Top Plunger] Top, Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-150030125 V DC / 250 V DC / 120/240 V AC3131.573.2--418.2±0.50PG13.5-1 Conduit Shape 2 Contact Seriesφ6Front mountingSlow action (direct circuit opening operation included)-1NC/1NO------------------

22.91 €

1 6 Days Plunger TypeSmall SizeStandard[Top Plunger] Top, Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-150030125 V DC / 250 V DC / 120/240 V AC3131.573.2--418.2±0.5-G1/2-1 Conduit Shape 2 Contact Seriesφ6Front mountingSlow action (direct circuit opening operation included)-1NC/1NO------------------

22.35 €

1 7 Days Plunger TypeSmall SizeStandard[Top Plunger] Top, Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-150030125 V DC / 250 V DC / 120/240 V AC3131.573.2--418.2±0.5-M20-1 Conduit Shape 2 Contact Seriesφ6Front mountingSlow action (direct circuit opening operation included)-1NC/1NO------------------

71.55 €

1 3 Days Plunger TypeSmall SizeStandard[Top Plunger] Top, Plunger---TUV / UL / GB(CCC) / EN6.5----2-circuit Double-break-1500-125 V DC / 250 V DC / 120/240 V AC3173.230-------------OtherPlungerOtherConnector M12OtherSlow-action switchCuboidfalsetrue0203060.550.27true

17.30 €

1 Available 14 Days Plunger TypeSmall SizeStandard[Top Plunger] Top, Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-150030125 V DC / 250 V DC / 120/240 V AC3131.573.2--418.2±0.50G1/2-1 Conduit Shape 2 Contact Seriesφ6Front mountingSnap action (direct circuit opening operation included)-1NC/1NO------------------

28.50 €

50 7 Days Plunger TypeSmall SizeStandard[Top Plunger] Top, Plunger---TUV / UL / GB(CCC) / EN6.52-6-2-circuit Double-break-150030125 V DC / 250 V DC / 120/240 V AC5631.556--418.2±0.5-M20-2 Conduit Shape 2 Contact Seriesφ6Front mountingSnap action (direct circuit opening operation included)-1NC/1NO------------------

Loading...

  1. 1

Basic information

Operating Temperature Range(°C) -30::70 Protective Structure IP67 Rated Current(A) 2.5

Tech Support