Miniature Safety Limit Switch [D4N] (D4N-122H)

Miniature Safety Limit Switch [D4N] D4N-122H
  • Volume Discount

Product Details:

Manufacturer part number: D4N-122H

Brand: OMRON

Price: 40.67

Delivery time: 3 Days


Technical Data:

Detector Shape: -

Kings of Plunger Type: -

Roller Lever Type: -

Lever Shape: -

Types of Rod Shape: -


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

D4N-122H

Part Number
D4N-122H
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Detector Shape Kings of Plunger Type Roller Lever Type Lever Shape Types of Rod Shape Force necessary for press side, O.F.
(N)
Movement up to switching, P.T.
(mm)
Angle up to switching, P.T.
(deg)
Maximum stroke T.T
(mm)
Maximum angle T.T
(deg)
Operation Frequency of Machine
(times/min. or Less)
Rated Operating Voltage
(V)
Rated Current
(A)
Main Body External Shape Width W
(mm)
Main Body External Shape Height H
(mm)
Main Body External Shape Depth D
(mm)
Lever length R
(mm)
Detector element details Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N▪m)
Conduit size Details Type Outer Diameter
(mm)
Mounting Method Direction of Operation Roller Type Contact format Degree of Protection (NEMA) Type of Control Element Alignment of the Control Element Type of Electric Connection Coating Housing Switching Function Construction Type Housing With Status Indication Forced Opening Number of Contacts as Change-Over Contact Number of Contacts as Normally Closed Contact Number of Contacts as Normally Open Contact Rated Operation Current Ie at AC-15, 230 V
(A)
Number of Safety Auxiliary Contacts Rated Operation Current Ie at AC-15, 125 V
(A)
Rated Operation Current Ie at DC-13, 125 V
(A)
Rated Operation Current Ie at DC-13, 230 V
(A)
Suitable for Safety Functions

40.67 €

1 3 Days -----4.5-------3113030------------OtherAdjustable roller leverRoller cam straightCable entry PGOtherQuick-break switchCuboidfalsetrue0203060.550.27true

Loading...

  1. 1

Basic information

Main Body Size Small Size Environment Standard Operating Temperature Range(°C) -30::70
Acquisition of Standard Approval TUV / UL / GB(CCC) / EN Protective Structure IP67 Contact type 2-circuit Double-break
Mechanical Life(x10K times) 1500

This page is Miniature Safety Limit Switch [D4N], part number D4N-122H.
You can find the detail information about specifications and dimensions on part number D4N-122H.

Variation of this product

Part Number
D4N-1122
D4N-112G
D4N-1172
D4N-1A20
D4N-1A2H
D4N-1A31
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Detector Shape Kings of Plunger Type Roller Lever Type Lever Shape Types of Rod Shape Force necessary for press side, O.F.
(N)
Movement up to switching, P.T.
(mm)
Angle up to switching, P.T.
(deg)
Maximum stroke T.T
(mm)
Maximum angle T.T
(deg)
Operation Frequency of Machine
(times/min. or Less)
Rated Operating Voltage
(V)
Rated Current
(A)
Main Body External Shape Width W
(mm)
Main Body External Shape Height H
(mm)
Main Body External Shape Depth D
(mm)
Lever length R
(mm)
Detector element details Movement After the Operation OT
(mm)
Operating Position OP
(mm)
Torque necessary for operation, OF
(N▪m)
Conduit size Details Type Outer Diameter
(mm)
Mounting Method Direction of Operation Roller Type Contact format Degree of Protection (NEMA) Type of Control Element Alignment of the Control Element Type of Electric Connection Coating Housing Switching Function Construction Type Housing With Status Indication Forced Opening Number of Contacts as Change-Over Contact Number of Contacts as Normally Closed Contact Number of Contacts as Normally Open Contact Rated Operation Current Ie at AC-15, 230 V
(A)
Number of Safety Auxiliary Contacts Rated Operation Current Ie at AC-15, 125 V
(A)
Rated Operation Current Ie at DC-13, 125 V
(A)
Rated Operation Current Ie at DC-13, 230 V
(A)
Suitable for Safety Functions

23.65 €

1 Same day

Stock

Roller Lever Type (rotation)-Standard--5-18-27-8030250 V DC / 125 V DC2.5314582.526Roller lever---PG13.51 Conduit Shape 2 Contact Seriesφ17.5×6.8Front mountingSnap action (direct circuit opening operation included)Metal lever / resin roller R261NC/1NO------------------

28.50 €

1 7 Days Roller Lever Type (rotation)-Variable Roller Levers--4.5-18-27-8030250 V DC / 125 V DC2.5314582.520-66Variable roller lever---PG13.51 Conduit Shape 2 Contact Seriesφ17.5×6.8Front mountingSnap action (direct circuit opening operation included)Metal lever / resin roller, foam lock type1NC/1NO------------------

29.47 €

1 7 Days Roller Lever Type (rotation)-Fork Lever Lock[Roller arm lever] Unidirectional Operation Seal Roller Arm Lever-54-9-30250 V DC / 125 V DC2.53131.56419Unidirectional operation roller arm lever type (vertical operation)527±0.8-PG13.51 Conduit Shape 2 Contact Seriesφ12.5 × 5Front mountingSnap action (direct circuit opening operation included)Resin Roller R191NC/1NO------------------

30.40 €

1 Same day

Stock

Roller Lever Type (rotation)-Standard--5-18-27-8030250 V DC / 125 V DC2.5314782.526Roller lever---PG13.51 Conduit Shape 2 Contact Seriesφ17.5×6.8Front mountingSlow action (direct circuit opening operation included)Resin lever / resin roller R261NC/1NO------------------

35.00 €

1 7 Days Roller Lever Type (rotation)-Variable Roller Levers--4.5-18-27-8030250 V DC / 125 V DC2.53148.282.532-66Variable roller lever---PG13.51 Conduit Shape 2 Contact Seriesφ50×8Front mountingSlow action (direct circuit opening operation included)Metal lever / rubber roller, foam lock type1NC/1NO------------------

24.90 €

1 7 Days Plunger Type[Top Plunger] Top, Plunger---6.52-6-30250 V DC / 125 V DC2.53131.573.2-Top plunger type (resin plunger)418.2±0.50PG13.51 Conduit Shape 2 Contact Seriesφ6Front mountingSlow action (direct circuit opening operation included)-1NC/1NO------------------

Tech Support