Manufacturer part number: E5EC-RX2ASM-011
Brand: OMRON
Price: 271.80 €
Delivery time: 6 Days
Input Method: Thermocouple / Platinum Resistance Thermometer / Voltage / Current
Control Output: Relay contact
Number of Control Points: 1 pcs.
Failure Detecting Function: Heater Breakage / SSR Breakdown
Setting Method: Key input
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
E5EC-RX2ASM-011
Part Number
|
---|
E5EC-RX2ASM-011 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Input Method | Control Output | Number of Control Points (pcs.) | Failure Detecting Function | Setting Method | Indicated Temperature Range (℃) | Type | Power Supply Voltage (V) | Control Output 1 | Control Output 2 | Auxiliary output points | Terminal shape | Event Input (Point) | Heater Breakage, SSR Fault Detection Capability | Input type | Communication | Remote SP input | Transmission input | Transmission Output | Width (mm) | Height (mm) | Depth (mm) | Number of Measuring Circuits | Number of Contacts as Normally Open Contact | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
271.80 € | 1 | 6 Days | Thermocouple / Platinum Resistance Thermometer / Voltage / Current | Relay contact | 1 | Heater Breakage / SSR Breakdown | Key input | -200~2300 | Temperature Controller / Controller | VAC 100–240 | Relay Output | NA | Independent 2-point | Screw Terminal Block Type | 6 | 1 points | - | - | - | - | - | 48 | 96 | - | - | - |
Loading...
Control Method | ON/OFF Control / PID control with auto tuning | Number of Input Points(pcs.) | 1 |
---|
This page is Digital Temperature Controller (48 × 96 mm) [E5EC], part number E5EC-RX2ASM-011.
You can find the detail information about specifications and dimensions on part number E5EC-RX2ASM-011.
Configure
Basic Attributes
Input Method
Failure Detecting Function
Input type
Communication
Remote SP input
Transmission input
Transmission Output
Depth(mm)
Number of Measuring Circuits
Number of Contacts as Normally Open Contact
Type
Control Output
Number of Control Points(pcs.)
Setting Method
Type
Power Supply Voltage(V)
Control Output 1
Control Output 2
Auxiliary output points
Terminal shape
Event Input(Point)
Heater Breakage, SSR Fault Detection Capability
Width(mm)
Height(mm)
Filter by CAD data type
Filter by standard shipping days
Optional Attributes
Part Number |
---|
E5AC-CX4ASM-000 |
E5AC-QX2ASM-008 |
E5AC-QX2ASM-010 |
E5EC-RX2DSM-000 |
E5EC-RX2DSM-011 |
E5EC-RX4A5M-000 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Input Method | Control Output | Number of Control Points (pcs.) | Failure Detecting Function | Setting Method | Indicated Temperature Range (℃) | Type | Power Supply Voltage (V) | Control Output 1 | Control Output 2 | Auxiliary output points | Terminal shape | Event Input (Point) | Heater Breakage, SSR Fault Detection Capability | Input type | Communication | Remote SP input | Transmission input | Transmission Output | Width (mm) | Height (mm) | Depth (mm) | Number of Measuring Circuits | Number of Contacts as Normally Open Contact |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
357.58 € | 1 | 13 Days | - | - | - | - | - | - | - | VAC 100–240 | Linear current output | NA | 4-point (auxiliary output 1, 2 common, auxiliary output 3, 4 common) | - | NA | - | - | - | - | - | - | - | - | - | - | - | ||
405.45 € | 1 | 13 Days | - | - | - | SSR Breakdown / Heater Breakage | - | - | - | VAC 100–240 | Voltage Output (for SSR Drive) | NA | Independent 2-point | - | 2 | 1 points | - | - | - | - | - | - | - | - | - | - | ||
330.22 € | 1 | 6 Days | - | - | - | SSR Breakdown / Heater Breakage | - | - | - | VAC 100–240 | Voltage Output (for SSR Drive) | NA | Independent 2-point | - | 4 | 1 points | - | - | - | - | - | - | - | - | - | - | ||
193.82 € | 1 | 21 Days | Platinum Resistance Thermometer / Thermocouple / Voltage / Current | Relay contact | 1 | NA | Key input | -200~2300 | Temperature Controller / Controller | AC/DC24V | Relay Output | NA | Independent 2-point | Screw Terminal Block Type | NA | - | - | - | - | - | - | 48 | 96 | - | - | - | ||
271.80 € | 1 | 6 Days | Platinum Resistance Thermometer / Thermocouple / Voltage / Current | Relay contact | 1 | SSR Breakdown / Heater Breakage | Key input | -200~2300 | Temperature Controller / Controller | AC/DC24V | Relay Output | NA | Independent 2-point | Screw Terminal Block Type | 6 | 1 points | - | - | - | - | - | 48 | 96 | - | - | - | ||
419.10 € | 1 | 3 Days | Platinum Resistance Thermometer / Thermocouple / Voltage / Current | Relay contact | 1 | NA | Key input | -200~2300 | Temperature Controller / Controller | VAC 100–240 | Relay Output | NA | - | Screw Terminal Block Type | - | - | - | - | - | - | - | 48 | 96 | 60 | 1 | 4 |