Soft Fluoropolymer Tubing TD / TID Series

Soft Fluoropolymer Tubing TD / TID Series

Click on this image to zoom in.

Click on this image to zoom in.

Compatible with Japan's Food Sanitation Law.
[Features]
・ Flexibility: About 20% improvement
・ Operating temperature is MAX.260°C
[Applications]
・ Ideal for use when flexibility is required

(i)Remark

  • The maximum operating pressure values listed are at 20°C or less. See the catalog for details.
  • For specifications and details, please refer to the catalog.
  • The last digits of the product codes indicate the length of the tubings.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Specifications of Soft Fluoropolymer Tubing TD Series

SizeMetric Size
NominalTD0425TD0604TD0806TD1075TD1209
Outer diameter (mm)4681012
Inner diameter (mm)2.5467.59
Roll10 m
20 m
ColorTranslucent (material color)
Applicable FluidsSee the catalog for applicable fluids.
FluidNote 1)Air, waterNote 1), inert gas
Applicable fittingsNote 1)Insert fittings KF Series
Stainless steel 316 insert fittings KFG2 Series
Miniature fittings M, MS Series (Hose-nipple type)
Fluoropolymer fittings LQ Series
Maximum operating pressure (MPa)20°C1.61.40.90.90.9
100°C0.90.70.50.50.5
200°C0.450.350.250.250.25
260°C0.230.20.150.150.15
Minimum bending radius mmNote 3)Recommended radius1525455575
Tube close bend radius816313541
Maximum operating temperature (fixed usage)260°C
MaterialModified PTFE (Polytetrafluoroethylene resin)

Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.

  • Use a tube above the recommended minimum bending radius.
  • The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
  • The tube close bend radius is not guaranteed. The value of 2R is measured with a bent or flattened tube.
Fluoropolymer Tubing TD/TID Series: related images

How to measure the minimum bending radius

Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.

Fluoropolymer Tubing TD/TID Series: related images

Maximum operating pressure

Specifications of Soft Fluoropolymer Tubing TID Series

SizeInch Size
NominalTID01TID05TID07TID11TID13
Outer diameterinch1/8 "3/16 "1/4 "3/8 "1/2 "
mm3.184.756.359.5312.7
Inner diameterinch0.086 "0.124 "
(1/8 ")
0.156 "
(5/32 ")
0.25 "
(1/4 ")
0.374 "
(3/8 ")
mm2.183.153.956.339.5
Roll8 m (25 ft)
16 m (50 ft)
ColorTranslucent (material color)
Applicable FluidsSee the catalog for applicable fluids.
FluidNote 1) Air, waterNote 1), inert gas
Applicable fittingsNote 2) Stainless steel 316 inert fittings KFG2 series
Fluoropolymer Fittings LQ Series
Maximum operating pressure (MPa)20°C1.41.41.61.40.9
100°C0.70.70.90.70.5
200°C0.350.350.450.350.25
260°C0.20.20.230.20.15
Minimum bending radius mmNote 3) Recommended radius1520254075
Tube close bend radius910152342
Maximum operating temperature (fixed usage)260°C
MaterialModified PTFE (Polytetrafluoroethylene resin)

Note 1) When using a liquid fluid, the surge pressure must be under the maximum operating pressure. If the surge pressure exceeds the maximum operating pressure, it will result in damage to the fittings and tubing. Furthermore, abnormal temperature rise caused by adiabatic compression may result in the tubing bursting.
Note 2) Do not use this product in a manner in which the tubing is not fixed. Observe the lesser value of the maximum operating pressure between the tubing and fittings. A material change over a long duration or due to high temperature may cause leakage. Perform periodic maintenance and replace with a new product immediately when abnormalities are detected.
Note 3) The minimum bending radius is the representative value measured as shown in the figure on the left.

  • Use a tube above the recommended minimum bending radius.
  • The tubing may be bent if used under the recommended minimum bending radius. Therefore, refer to the tube close bend radius and make sure that the tubing is not bent or flattened.
  • The tube close bend radius is not guaranteed. The value of 2R is measured with a bent or flattened tube.
Fluoropolymer Tubing TD/TID Series: related images

How to measure the minimum bending radius

Bend the tubing into a U shape at a temperature of 20°C. Fix one end and close the loop gradually. Measure 2R when the deformed ratio of the tubing diameter at bending reaches 5%.

Fluoropolymer Tubing TD/TID Series: related images

Maximum operating pressure

Part Number
TD0806-10
TD0806-20
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Outer Diameter D
(Ø)
O.D. [Distinction] Inner Diameter d
(Ø)
I.D. [Distinction] Minimum Bending Radius
(mm)
Bundle winding length
(m)
Applicable Tube Size Maximum operating pressure
(MPa)

186.23 €

1 26 Days 8Up to 86Up to 64510Metric Size0.9

372.39 €

1 4 Days 8Up to 86Up to 64520Metric Size0.9

Loading...

  1. 1

Basic information

Type Straight Cutting Service Usage NA Material Fluororesin
Applicable Fluid Water / Air Operating Environment Standard / Chemical Resistance Color Blue (Translucent)
Operating temperature(°C) up to 260

Tech Support

Technical Support
Tel:+49 69 668173-0 / FAX:+49 69 668173-360