Manufacturer part number: XLA-16-2
Brand: SMC
Price: 440.40 €
Delivery time: 4 Days
Flange Type: NW
Flange Calls: 16
Indicator: No indicator
Pilot Port Direction: Flange side
Switch Part Number: No auto-switch (no magnet)
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
XLA-16-2
XLA external appearance (side)
Model | XLA-16 | XLA (V)-25 | XLA-40 | XLA-50 | XLA-63 | XLA-80 | |
---|---|---|---|---|---|---|---|
Valve Type | Normally closed (pressurize to open, spring seal) | ||||||
Fluids | Inert gas under vacuum | ||||||
Operating Temperature (°C) | XLA | 5 to 60 (5 to 150 for high temperature type) | |||||
Operating Pressure Pa (abs) | 1 × 10-6 to atmospheric pressure | ||||||
Conductance L/s Note 1: | 5 | 14 | 45 | 80 | 160 | 200 | |
Leakage Pa·m3/s | Internal | For standard material (FKM): 1.3 × 10-10, values at normal temperature and excluding gas permeation | |||||
External | For standard material (FKM): 1.3 × 10-11, values at normal temperature and excluding gas permeation | ||||||
Flange Type | KF (NW) | KF (NW) / K (DN) | |||||
Principal Material | Main body: aluminum alloy, Bellows: Stainless steel 316L, Main parts: Stainless steel, FKM (standard sealing material) | ||||||
Surface Treatment | External: hard anodized aluminum, Internal: raw material | ||||||
Pilot Pressure MPa (G) | 0.4 to 0.7 | ||||||
Pilot Port Size | XLA | M5 | Rc 1/8 | ||||
Weight (kg) | XLA | 0.25 | 0.45 | 1.1 | 1.6 | 2.9 | 5.0 |
Note 1: Conductance is the same as that of an elbow with the same dimensions.
With solenoid valve
Valve side exhaust
By applying pressure from the pilot port, the valve linked to the piston overcomes the spring force and actuating force and opens.
XLAV normally applies pilot pressure to the 1 (P) port. The valve opens when the solenoid valve is on and closes when it is off.
XLA air-operated type dimensional drawing
Note: A, B, and C in the figure above indicate the heater mounting positions. The heater mounting positions differ by the heater type. Refer to the manufacturer's catalog for more details.
(Unit: mm)
Model | A | B | C | D | E Note 1: | Fn | Fd | G | H |
---|---|---|---|---|---|---|---|---|---|
XLA-16 | 40 | 103 | 38 | 1 | - | 30 | - | 17 | 40 |
XLA-25 | 50 | 113 | 48 | 1 | 12 | 40 | - | 26 | 39 |
XLA-40 | 65 | 158 | 66 | 2 | 11 | 55 | - | 41 | 63 |
XLA-50 | 70 | 170 | 79 | 2 | 11 | 75 | - | 52 | 68 |
XLA-63 | 88 | 196 | 100 | 3 | 11 | 87 | 95 | 70 | 69 |
XLA-80 | 90 | 235 | 117 | 3 | 11 | 114 | 110 | 83 | 96 |
Note 1: Dimension E applies when heater option is included. (Lead wire length: approx. 1 m)
Part Number
|
---|
XLA-16-2 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Flange Type | Flange Calls | Indicator | Pilot Port Direction | Switch Part Number | Seal material | Seal Change Location | |
---|---|---|---|---|---|---|---|---|---|---|---|
440.40 € | 1 | 4 Days | NW | 16 | No indicator | Flange side | No auto-switch (no magnet) | FKM (Formula No.: 1349-80) | None |
Loading...
Type | Vacuum operation vacuum valves | Application | Single Item Operating | Installation method | Direct |
---|---|---|---|---|---|
Number of Ports | 3-port valve | Types of solenoid | Single | Switching Type | 2-position Normally Closed |
Pipe Port Type | Flange | Seal Type | Bellows seal | Temperature Range(°C) | 5 to 60℃ (no heater) |
Body Surface Treatment | External: hard anodized aluminum, Internal: base material |
This page is XLA-2, Aluminium High Vacuum Angle Valve, Normally Closed / Bellows Seal, part number XLA-16-2.
You can find the detail information about specifications and dimensions on part number XLA-16-2.
Configure
Basic Attributes
Type
Flange Type
Flange Calls
Indicator
Pilot Port Direction
Switch Part Number
Seal material
Seal Change Location
Filter by CAD data type
Filter by standard shipping days
Optional Attributes
Part Number |
---|
XLA-16-2-XN1A |
XLA-25-2 |
XLA-25-2M9//-XQ1A |
XLA-25A-2 |
XLA-25G-2-XN1A |
XLA-25G-2M9// |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Flange Type | Flange Calls | Indicator | Pilot Port Direction | Switch Part Number | Seal material | Seal Change Location |
---|---|---|---|---|---|---|---|---|---|---|---|
447.73 € | 1 | 26 Days | NW | 16 | No indicator | Flange side | No auto-switch (no magnet) | EPDM (Formula No.: 2101-80) | Valve seal 1 / valve seal 2 / external seal | ||
458.71 € | 1 | 4 Days | NW | 25 | No indicator | Flange side | No auto-switch (no magnet) | FKM (Formula No.: 1349-80) | None | ||
783.49 € | 1 | 26 Days | NW | 25 | No indicator | Flange side | No auto-switch (with magnet) | Kalrez (Formula No.: 4079) | Valve seal 1 / valve seal 2 / external seal | ||
437.59 € | 1 | 98 Days | NW | 25 | With indicator | Flange side | No auto-switch (no magnet) | FKM (Formula No.: 1349-80) | None | ||
471.39 € | 1 | 26 Days | NW | 25 | With indicator | Flange surface, back | No auto-switch (no magnet) | EPDM (Formula No.: 2101-80) | Valve seal 1 / valve seal 2 / external seal | ||
466.96 € | 1 | 4 Days | NW | 25 | With indicator | Flange surface, back | No auto-switch (with magnet) | FKM (Formula No.: 1349-80) | None |