Vacuum Switch, Diaphragm Style, ZSM1 (ZSM1-015)

Vacuum Switch, Diaphragm Style, ZSM1 ZSM1-015

Product Details:

Manufacturer part number: ZSM1-015

Brand: SMC

Price: 86.84

Delivery time: 26 Days


Technical Data:

Pipe Port Type: [Direct Mount] ZM Ejector Mount

Plumbing Thread Type: -

Nominal Pipe Thread Size: -

Operating Temperature Range: -5~60 ℃

No. of Inputs: 1


(i)Remark

  • Product images may be representative images. Refer to the manufacturer's catalog for details

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

ZSM1-015

Specifications of Vacuum Pressure Switch / Diaphragm Type

External appearance of vacuum pressure switch / diaphragm type

External appearance of vacuum pressure switch / diaphragm type

Connection method of ZSM1-115

Connection method of ZSM1-115

Internal circuit of ZSM1-115

Internal circuit of ZSM1-115

  • Brown lead wire: Connect to the power supply (+) terminal is necessary to operate the switch main circuit.
  • Black lead wire: Connect to the load. (PLC input, relay)
  • Blue lead wire: Connect to the power supply GND terminal.
Internal circuit of ZSM1-121

Internal circuit of ZSM1-121

Specifications

ModelZSM1-115ZSM1-121
Switch specificationsSolid stateContact (Reed Switch)
FluidAir and inert gas
Maximum operating pressure0.5 MPa
Set pressure range-27 to -80 kPa
HysteresisMax. 15 kPaMax. 20 kPa
Repeat accuracy±10% or less
Ambient and fluid temperature-5~+60℃ (No freezing)
Supply voltageDC4.5 to 28 V100 V AC/DC or less
Indicator LightON lights
Lead number32
Port SizeR1/8
Weight65 g

Electrical Specifications

ZSM1-115

  • Supply voltage: DC4.5 to 28 V
  • Output (Open Collector): 28 V. Max 40 mA
  • Current Consumption: 10 mA or less (DC24V)

ZSM1-121

  • Supply voltage: AC/DC100V
  • Maximum operating current range: 24 V or less: 50 mA, 48 V: 40 mA, 100 V: 20 mA
  • Max. Contact Capacity: AC2VA, DC2W

Dimensions

 

(Units: mm)

 

Dimensional drawing of vacuum pressure switch / diaphragm type

Dimensional drawing of vacuum pressure switch / diaphragm type

Dimensional drawing of ZSM1-115

Dimensional drawing of ZSM1-115

Dimensional drawing of ZSM1-121

Dimensional drawing of ZSM1-121

Notes

Wiring

Contact protection box internal circuit

Contact protection box internal circuit

  1. * 1Do not apply pulling force to the power cord. It may cause damage.
  2. * 2Wiring precautions for ZSM1-121: When ZSM1-121 is connected in series, a voltage drop occurs due to the internal resistance of the light emitting diode. The voltage drop is approx. 2 V per switch. After checking the minimum drive voltage on the drive side, use within the range possible.
  3. * 3Since it does not have a built-in contact protection circuit, use the contact protection box (CD-P11) with an inductive load or a lead wire of 5 m or longer.
  4. * 4Contact protection box / connection method: To connect the switch body to the contact protection box, connect the lead wire on the side labeled SWITCH on the contact protection box and the lead wire from the switch body. Also, keep the lead wire length between the switch body and the contact protection box within 1 m, and set it as close as possible.

Mounting/Piping

The main body must not be turned with a wrench

The main body must not be turned with a wrench

  1. * 1When handling the product, always hold it by the body and do not apply pulling force to the power cord.
  2. * 2When handling, do not drop or hit. It may cause damage.
  3. * 3When mounting on the pipe, apply a wrench to the fitting and screw in. Turning the main body with a wrench may cause damage.
  4. * 4The mounting direction can be horizontal or vertical.

Pressure source

  1. * 1When used as a suction confirmation switch, do not suck in water. It may cause malfunction or damage
  2. * 2Operating fluids are dedicated for air and inert gas. Corrosive fluid cannot be used.
  • *See the SMC catalog for information other than that detailed above.
Part Number
ZSM1-015
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Pipe Port Type Plumbing Thread Type Nominal Pipe Thread Size Operating Temperature Range
(℃)
No. of Inputs Power Supply Type Power Supply Voltage
(V)
Acquired Standards Lead Wire Hysteresis
(MPa)

86.84 €

1 26 Days [Direct Mount] ZM Ejector Mount---5~601DC4.5 to 28CE0.5 m0.015

Loading...

  1. 1

Basic information

Type Pressure Switch Fluid Type Air / Nitrogen Gas / Carbonic Acid Gas / City Gas / Methane Gas / Propane gas Sensor/Monitor Configuration Separate Type, Connector Joint
Output Method Switch Fluid Characteristics Inert No. of Outputs 1
Pipe Connection Direction Down

This page is Vacuum Switch, Diaphragm Style, ZSM1, part number ZSM1-015.
You can find the detail information about specifications and dimensions on part number ZSM1-015.

Variation of this product

Part Number
ZSM1-015L
ZSM1-021
ZSM1-021L
ZSM1-115
ZSM1-115L
ZSM1-121
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Pipe Port Type Plumbing Thread Type Nominal Pipe Thread Size Operating Temperature Range
(℃)
No. of Inputs Power Supply Type Power Supply Voltage
(V)
Acquired Standards Lead Wire Hysteresis
(MPa)

93.73 €

1 26 Days [Direct Mount] ZM Ejector Mount---5~601DC4.5 to 28CE3 m0.015

68.56 €

1 26 Days [Direct Mount] ZM Ejector Mount---5~601AC/DC100CE0.5 m0.02

75.45 €

1 4 Days [Direct Mount] ZM Ejector Mount----AC/DC100-3-

86.84 €

1 22 Days [Threads] Male thread[Rc (R)] R[1/8] 1/8--DC4.5 to 28-0.5 m-

93.73 €

1 22 Days [Threads] Male thread[Rc (R)] R[1/8] 1/8--DC4.5 to 28-3-

68.56 €

1 22 Days [Threads] Male thread[Rc (R)] R[1/8] 1/8-5~60-AC/DC100-0.5 m-

Tech Support