Max. Current Load per OSSD Output: 400; (24 V) mA
Number of Beams: 3
Active/Passive System: -
Protection: IP 65; IP 67; IP 69K; (with protective tube: IP 69K)
Power-On Delay Time: < 2 s
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
OY412S
Part Number
|
---|
OY412S |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Max. Current Load per OSSD Output (mA) | Number of Beams | Active/Passive System | Protection | Power-On Delay Time (s) | Materials | Current Consumption (mA) | Protective Function | Application | Electrical Connection - Transmitter | Storage Temperature (°C) | Electrical Connection | Ambient Temperature (°C) | Protection Area Width (Low Light Intensity) (m) | Length (mm) | Current Consumption Heating (mA) | Protected Area Height (mm) | Max. Relative Air Humidity (%) | Operating Voltage Tolerance (%) | Electrical Connection - Receiver | Dimensions (mm) | Display | Protection Area Width (High Light Intensity) (m) | Accessories (Included) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2,555.22 € | 1 | 4 Days | 400; (24 V) | 3 | - | IP 65; IP 67; IP 69K; (with protective tube: IP 69K) | < 2 | thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone | 83|42 | access prevention body protection | - | Cable: 15 m, PVC; 8 x 0.34 mm² | - | - | -20-55 | 0-3 | 1077 | 417 | 810 | 95 | 20 | Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm² | Ø 56 / L = 1077 | transmitter: 1 x LEDreceiver: 2 x LED | 2-10 | - |
Loading...
Electrical Design | PNP | Wave Length(nm) | 950 | Protection Class | III |
---|---|---|---|---|---|
Operating Voltage(V) | 24 DC | Reverse Polarity Protection | Yes | Short-Circuit Protection | Yes |
Type of Light | Infrared light | Number of OSSD Outputs | 2 |
This page is Safety Light Grid, part number OY412S.
You can find the detail information about specifications and dimensions on part number OY412S.
Configure
Basic Attributes
Active/Passive System
Application
Storage Temperature(°C)
Electrical Connection
Accessories (Included)
Max. Current Load per OSSD Output(mA)
Number of Beams
Protection
Power-On Delay Time(s)
Materials
Current Consumption(mA)
Protective Function
Electrical Connection - Transmitter
Ambient Temperature(°C)
Protection Area Width (Low Light Intensity)(m)
Length(mm)
Current Consumption Heating(mA)
Protected Area Height(mm)
Max. Relative Air Humidity(%)
Operating Voltage Tolerance(%)
Electrical Connection - Receiver
Dimensions(mm)
Display
Protection Area Width (High Light Intensity)(m)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
OY114S |
OY115S |
OY116S |
OY413S |
OY421S |
OY422S |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Max. Current Load per OSSD Output (mA) | Number of Beams | Active/Passive System | Protection | Power-On Delay Time (s) | Materials | Current Consumption (mA) | Protective Function | Application | Electrical Connection - Transmitter | Storage Temperature (°C) | Electrical Connection | Ambient Temperature (°C) | Protection Area Width (Low Light Intensity) (m) | Length (mm) | Current Consumption Heating (mA) | Protected Area Height (mm) | Max. Relative Air Humidity (%) | Operating Voltage Tolerance (%) | Electrical Connection - Receiver | Dimensions (mm) | Display | Protection Area Width (High Light Intensity) (m) | Accessories (Included) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1,298.11 € | 1 | 4 Days | 400; (24 V) | 2 | - | IP 65; IP 67 | < 2 | Housing: aluminium; front lens: PC | 83|42 | access prevention body protection | class C to EN 60654-1 weatherproof application | Connector: 1 x M12 | -20-70 | - | -10-55 | 0-4 | 653 | - | 510 | 95 | 20 | Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm² | 653 x 28 x 30 | LED, yellow LED, green LED, red | 3-12 | Mounting bracket: 4 slot nuts: 4 Nuts | ||
1,503.50 € | 1 | 4 Days | 400; (24 V) | 3 | - | IP 65; IP 67 | < 2 | Housing: aluminium; front lens: PC | 83|42 | access prevention body protection | class C to EN 60654-1 weatherproof application | Connector: 1 x M12 | -20-70 | - | -10-55 | 0-4 | 953 | - | 810 | 95 | 20 | Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm² | 953 x 28 x 30 | LED, yellow LED, green LED, red | 3-12 | Mounting bracket: 4 slot nuts: 4 Nuts | ||
1,753.93 € | 1 | 4 Days | 400; (24 V) | 4 | - | IP 65; IP 67 | < 2 | Housing: aluminium; front lens: PC | 83|42 | access prevention body protection | class C to EN 60654-1 weatherproof application | Connector: 1 x M12 | -20-70 | - | -10-55 | 0-4 | 1053 | - | 910 | 95 | 20 | Connector: 1 x M12; Maximum cable length: 100 m; for wire cross-section 0.34 mm² | 1053 x 28 x 30 | LED, yellow LED, green LED, red | 3-12 | Mounting bracket: 4 slot nuts: 4 Nuts | ||
2,721.77 € | 1 | 4 Days | 400; (24 V) | 4 | - | IP 65; IP 67; IP 69K; (with protective tube: IP 69K) | < 2 | thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone | 83|42 | access prevention body protection | - | Cable: 15 m, PVC; 8 x 0.34 mm² | - | - | -20-55 | 0-3 | 1177 | 417 | 910 | 95 | 20 | Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm² | Ø 56 / L = 1177 | transmitter: 1 x LEDreceiver: 2 x LED | 2-10 | - | ||
2,575.95 € | 1 | 4 Days | 400; (24 V) | 2 | - | IP 65; IP 67; IP 69K; (with protective tube: IP 69K) | < 2 | thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone | 83|42 | access prevention body protection | - | Cable: 15 m, PVC; 8 x 0.34 mm² | - | - | -20-55 | 0-7 | 777 | 333 | 510 | 95 | 20 | Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm² | Ø 56 / L = 777 | transmitter: 1 x LEDreceiver: 2 x LED | 3-15 | - | ||
2,880.51 € | 1 | 4 Days | 400; (24 V) | 3 | - | IP 65; IP 67; IP 69K; (with protective tube: IP 69K) | < 2 | thermowell: PMMA transparent; Protective cap: POM; clamp: stainless steel (1.4404 / 316L); Sealing: silicone | 83|42 | access prevention body protection | - | Cable: 15 m, PVC; 8 x 0.34 mm² | - | - | -20-55 | 0-7 | 1077 | 417 | 810 | 95 | 20 | Cable: 15 m, PVC; Maximum cable length: 100 m; 10 x 0.34 mm² | Ø 56 / L = 1077 | transmitter: 1 x LEDreceiver: 2 x LED | 3-15 | - |