Manufacturer part number: PNI023
Brand: IFM ELECTRONIC
Price: 650.96 €
Delivery time: 4 Days
Number of Inputs and Outputs: Number of digital outputs: 2
Parameter: -
Max. Voltage Drop Switching Output AC: - V
Min. Pressure Cycles: 100 million
Protection: IP 65
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
PNI023
Part Number
|
---|
PNI023 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Parameter | Max. Voltage Drop Switching Output AC (V) | Min. Pressure Cycles | Protection | Min. Bursting Pressure (kPa) | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Current Consumption (mA) | Protection Class | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Process Connection | Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Min. Bursting Pressure (MPa) | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Reverse Polarity Protection | Permanent Current Rating of Switching Output AC (mA) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | IO-Link Resolution Pressure (MPa) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Operating Voltage Tolerance (%) | Switching Cycles (Mechanical) | Switching Frequency AC (Hz) | Nominal Voltage AC (V) | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | Analogue Input (Current) (mA) | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Analogue Input (Voltage) (V) | Measuring Range (MPa) | Installation | Display | Materials (Wetted Parts) | Transmission Type | Min. Bursting Pressure (bar) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
650.96 € | 1 | 4 Days | Number of digital outputs: 2 | - | - | 100 million | IP 65 | - | PNP/NPN | - | 0-25 | stainless steel (1.4305 / 303); PBT; PC; PA; FKM | < 90 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 internal thread | - | - | 18-30 DC | - | Connector: 1 x M12; Contacts: gold-plated | - | -25-80 | - | - | Yes | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 300 | < 170 | 90000 | - | No (can be retrofitted) | Switching signal | Yes | - | - | - | - | - | - | Gold-plated contacts | Liquids and gases | 0-20 | Yes | - | 100; (500 V DC) | - | - | 0-10 | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | 350 | - | relative pressure |
Loading...
This page is Electronic Pressure Monitor, part number PNI023.
You can find the detail information about specifications and dimensions on part number PNI023.
Configure
Basic Attributes
Parameter
Max. Voltage Drop Switching Output AC(V)
Min. Bursting Pressure(kPa)
MAWP (for Applications According to CRN)(bar)
Measuring Range(kPa)
Conditionally Suitable For
Connection
Measuring Element
IO-Link Resolution Temperature(K)
Min. Bursting Pressure(MPa)
Process Connection Sealing
Overvoltage Protection
Permanent Current Rating of Switching Output AC(mA)
IO-Link Resolution Pressure(MPa)
Operating Voltage Tolerance(%)
Switching Cycles (Mechanical)
Switching Frequency AC(Hz)
Nominal Voltage AC(V)
Communication Interface
Tightening Torque(Nm)
No Dead Space
Short-Circuit Proof
IO-Link Revision
Measuring Range(MPa)
Installation
Display
Transmission Type
MAWP (for Applications According to CRN)(mbar)
Number of Inputs and Outputs
Min. Pressure Cycles
Protection
Electrical Design
Measuring Range(bar)
Materials
Current Consumption(mA)
Protection Class
Application
Type of Short-Circuit Protection
Process Connection
Operating Voltage(V)
Electrical Connection
Ambient Temperature(°C)
Reverse Polarity Protection
Output Function
Medium Temperature(°C)
Total Number of Outputs
Max. Load(Ω)
Switching Frequency DC(Hz)
Min. Load Resistance(Ω)
Restrictor Element Integrated
Output Signal
Short-Circuit Protection
Special Feature
Application Media
Analogue Input (Current)(mA)
Overload Protection
Min. Insulation Resistance(MΩ)
Analogue Input (Voltage)(V)
Materials (Wetted Parts)
Min. Bursting Pressure(bar)
Type of Pressure
Filter by standard shipping days
Optional Attributes
Part Number |
---|
PK5520 |
PK5521 |
PK5522 |
PNI024 |
PV2123 |
PV7000 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Parameter | Max. Voltage Drop Switching Output AC (V) | Min. Pressure Cycles | Protection | Min. Bursting Pressure (kPa) | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Current Consumption (mA) | Protection Class | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Process Connection | Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Min. Bursting Pressure (MPa) | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Reverse Polarity Protection | Permanent Current Rating of Switching Output AC (mA) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | IO-Link Resolution Pressure (MPa) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Operating Voltage Tolerance (%) | Switching Cycles (Mechanical) | Switching Frequency AC (Hz) | Nominal Voltage AC (V) | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | Analogue Input (Current) (mA) | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Analogue Input (Voltage) (V) | Measuring Range (MPa) | Installation | Display | Materials (Wetted Parts) | Transmission Type | Min. Bursting Pressure (bar) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
175.55 € | 1 | 4 Days | Number of digital outputs: 1 | - | - | 50 million | IP 67 | - | PNP | - | 0-400 | PBT; PC; FKM; stainless steel (1.4404 / 316L) | < 25 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 external thread internal thread:M5 | - | - | 9.6-32 DC | - | Connector: 1 x M12 | - | -25-80 | - | - | Yes | - | normally open | -25-80 | 1 | - | 100 | - | - | No (can be retrofitted) | Switching signal | Yes | - | - | - | - | - | 25 | - | Liquids and gases | - | Yes | - | 100; (500 V DC) | - | - | - | - | - | operation: LED, green switching status: LED, yellow With scale: Yes | stainless steel (1.4404 / 316L); FKM | - | - | - | - | ||
170.59 € | 1 | 4 Days | Number of digital outputs: 1 | - | - | 50 million | IP 67 | - | PNP | - | 0-250 | PBT; PC; FKM; stainless steel (1.4404 / 316L) | < 25 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 external thread internal thread:M5 | - | - | 9.6-32 DC | - | Connector: 1 x M12 | - | -25-80 | - | - | Yes | - | normally open | -25-80 | 1 | - | 100 | - | - | No (can be retrofitted) | Switching signal | Yes | - | - | - | - | - | 25 | - | Liquids and gases | - | Yes | - | 100; (500 V DC) | - | - | - | - | - | operation: LED, green switching status: LED, yellow With scale: Yes | stainless steel (1.4404 / 316L); FKM | - | - | - | - | ||
170.59 € | 1 | 4 Days | Number of digital outputs: 1 | - | - | 50 million | IP 67 | - | PNP | - | 0-100 | PBT; PC; FKM; stainless steel (1.4404 / 316L) | < 25 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 external thread internal thread:M5 | - | - | 9.6-32 DC | - | Connector: 1 x M12 | - | -25-80 | - | - | Yes | - | normally open | -25-80 | 1 | - | 100 | - | - | No (can be retrofitted) | Switching signal | Yes | - | - | - | - | - | 25 | - | Liquids and gases | - | Yes | - | 100; (500 V DC) | - | - | - | - | - | operation: LED, green switching status: LED, yellow With scale: Yes | stainless steel (1.4404 / 316L); FKM | - | - | - | - | ||
650.96 € | 1 | 4 Days | Number of digital outputs: 2 | - | - | 100 million | IP 65 | - | PNP/NPN | - | 0-10 | stainless steel (1.4305 / 303); PBT; PC; PA; FKM | < 90 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 internal thread | - | - | 18-30 DC | - | Connector: 1 x M12; Contacts: gold-plated | - | -25-80 | - | - | Yes | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | 300 | < 170 | 90000 | - | No (can be retrofitted) | Switching signal | Yes | - | - | - | - | - | - | Gold-plated contacts | Liquids and gases | 0-20 | Yes | - | 100; (500 V DC) | - | - | 0-10 | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | 150 | - | relative pressure | ||
172.48 € | 1 | 3 Days | Number of digital outputs: 2 | - | - | 60 million; (at 1.2 times nominal pressure) | IP 67; IP 69K | - | PNP/NPN | - | 0-60 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI | < 15 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 | - | metallic thin film cell | 18-30 DC | - | Connector: 1 x M12 | - | -40-90 | FKM (to DIN 3869) | - | Yes | - | normally open / normally closed; (parameterisable) | -40-90 | 2 | - | < 170 | - | - | No (can be retrofitted) | Switching signal; IO-Link; (configurable) | Yes | - | - | - | - | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | - | - | - | 1.4542 (17-4 PH / 630) | COM2 (38.4 kBaud) | 900 | - | - | ||
177.69 € | 1 | 4 Days | Number of digital outputs: 2 | - | - | 60 million; (at 1.2 times nominal pressure) | IP 67; IP 69K | - | PNP/NPN | - | 0-400 | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PEI | < 15 | III | - | For industrial applications | - | pulsed | threaded connection G 1/4 external thread (DIN EN ISO 1179-2); internal thread:M5 | - | metallic thin film cell | 18-30 DC | - | Connector: 1 x M12 | - | -40-90 | FKM (to DIN 3869) | - | Yes | - | normally open / normally closed; (parameterisable) | -40-90 | 2 | - | < 170 | - | - | Yes | Switching signal; IO-Link; (configurable) | Yes | - | - | - | - | IO-Link | 25-35; (recommended tightening torque; depends on lubrication. seal and pressure rating) | - | Liquids and gases | - | Yes | - | 100; (500 V DC) | - | 1.1 | - | - | - | - | stainless steel (1.4305 / 303); 1.4542 (17-4 PH / 630) | COM2 (38.4 kBaud) | - | - | - |