Flow Sensor (SA4100)

Flow Sensor SA4100

Product Details:

Manufacturer part number: SA4100

Brand: IFM ELECTRONIC

Price: 423.86

Delivery time: 4 Days


Technical Data:

Pressure Rating: - bar

Number of Inputs and Outputs: Number of digital outputs: 2; Number of analogue outputs: 1

Mounting Orientation: -

Protection: IP 65; IP 67

Power-On Delay Time: 10 s


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

SA4100

Part Number
SA4100
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Pressure Rating
(bar)
Number of Inputs and Outputs Mounting Orientation Protection Power-On Delay Time
(s)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Materials Current Consumption
(mA)
Protection Class Application Type of Short-Circuit Protection Process Connection Operating Voltage
(V)
Electrical Connection Ambient Temperature
(°C)
Reverse Polarity Protection Output Function Medium Temperature
(°C)
Output Signal Housing Switching Cycles (Mechanical) Communication Interface Special Feature Application Media Probe Length
(mm)
Installation Length EL
(mm)
Pressure Rating
(MPa)
Ambient Temperature
(°F)
Connection to Control Monitor IO-Link Revision Installation Dimensions
(mm)
Display Materials (Wetted Parts) Transmission Type Accessories (Included)

423.86 €

1 4 Days -Number of digital outputs: 2; Number of analogue outputs: 1-IP 65; IP 6710PNP/NPN-stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30< 100III-pulsedDameter Ø 8 mm18-30 DCConnector: 1 x M12; Contacts: gold-plated-40-80Yesnormally open / normally closed; (parameterisable)-Switching signal; analogue signal; frequency signal; IO-Link; (configurable)--IO-LinkGold-plated contactswater; glycol solutions; air; oils100----1.1--Display unit: 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L)COM2 (38.4 kBaud)-

Loading...

  1. 1

This page is Flow Sensor, part number SA4100.
You can find the detail information about specifications and dimensions on part number SA4100.

Variation of this product

Part Number
SA2000
SA2004
SA4104
SA4110
SA4114
SA4120
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Pressure Rating
(bar)
Number of Inputs and Outputs Mounting Orientation Protection Power-On Delay Time
(s)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Materials Current Consumption
(mA)
Protection Class Application Type of Short-Circuit Protection Process Connection Operating Voltage
(V)
Electrical Connection Ambient Temperature
(°C)
Reverse Polarity Protection Output Function Medium Temperature
(°C)
Output Signal Housing Switching Cycles (Mechanical) Communication Interface Special Feature Application Media Probe Length
(mm)
Installation Length EL
(mm)
Pressure Rating
(MPa)
Ambient Temperature
(°F)
Connection to Control Monitor IO-Link Revision Installation Dimensions
(mm)
Display Materials (Wetted Parts) Transmission Type Accessories (Included)

418.64 €

1 4 Days -Number of digital outputs: 2; Number of analogue outputs: 1-IP 65; IP 6710PNP/NPN-stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30< 100III-pulsedthreaded connection G 1/218-30 DCConnector: 1 x M12; Contacts: gold-plated-40-80Yesnormally open / normally closed; (parameterisable)-Switching signal; analogue signal; frequency signal; IO-Link; (configurable)--IO-LinkGold-plated contactswater; glycol solutions; air; oils19.2----1.1--Display unit: 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L); Gasket: FKMCOM2 (38.4 kBaud)-

430.72 €

1 4 Days -Number of analogue outputs: 2-IP 65; IP 6710--stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PBT-GF20; PBT-GF30< 100III-pulsedthreaded connection G 1/218-30 DCConnector: 1 x M12; Contacts: gold-plated-40-80Yes--Analogue signal---Gold-plated contactswater; glycol solutions; air; oils19.2-------Display unit: 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L); Gasket: FKM--

431.91 €

1 4 Days -Number of analogue outputs: 2-IP 65; IP 6710--stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30< 100III-pulsedDameter Ø 8 mm18-30 DCConnector: 1 x M12; Contacts: gold-plated-40-80Yes--Analogue signal---Gold-plated contactswater; glycol solutions; air; oils100-------Display unit: 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L)--

423.86 €

1 4 Days -Number of digital outputs: 2; Number of analogue outputs: 1-IP 65; IP 6710PNP/NPN-stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30< 100III-pulsedDameter Ø 8 mm18-30 DCConnector: 1 x M12; Contacts: gold-plated-Yesnormally open / normally closed; (parameterisable)-Switching signal; analogue signal; frequency signal; IO-Link; (configurable)--IO-LinkGold-plated contactswater; glycol solutions; air; oils100---40-176-1.1--Display unit: 6 x LED, green (%, fps, gpm, cfm, °F, 10³)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L)COM2 (38.4 kBaud)-

440.09 €

1 4 Days -Number of analogue outputs: 2-IP 65; IP 6710--stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30< 100III-pulsedDameter Ø 8 mm18-30 DCConnector: 1 x M12; Contacts: gold-plated-Yes--Analogue signal---Gold-plated contactswater; glycol solutions; air; oils100---40-176----Display unit: 6 x LED, green (%, fps, gpm, cfm, °F, 10³)
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L)--

440.80 €

1 4 Days 50Number of digital outputs: 2; Number of analogue outputs: 1-IP 65; IP 6710PNP/NPN50stainless steel (1.4404 / 316L); PBT-GF20; PBT-GF30< 100III-pulsedDameter Ø 8 mm18-30 DC; (according to EN 50178 SELV/PELV)Connector: 1 x M12; Contacts: gold-plated-40-80Yesnormally open / normally closed; (parameterisable)-20-100Switching signal; analogue signal; frequency signal; IO-Link; (configurable)--IO-LinkGold-plated contactsAir100-5--1.1Adjustable to inside pipe diameters; ( 15-400 mm)-Display unit: 6 x LED, green (%, m/s, l/min, m³/h, °C, 10³)
switching status: 2 x LED, yellow
measured values: alphanumeric display, red/green 4-digit
stainless steel (1.4404 / 316L)COM2 (38.4 kBaud)-