Electronic Level Sensor (LMT292)

Electronic Level Sensor LMT292

Product Details:

Manufacturer part number: LMT292

Brand: IFM ELECTRONIC

Price: 298.66

Delivery time: 4 Days


Technical Data:

Number of Inputs and Outputs: Number of digital outputs: 2

Analogue Voltage Output: - V

Protection: -

Power-On Delay Time: - s

Electrical Design: PNP


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

LMT292

Part Number
LMT292
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Number of Inputs and Outputs Analogue Voltage Output
(V)
Protection Power-On Delay Time
(s)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Materials Current Consumption
(mA)
Application Electrical Connection - Plug Type of Short-Circuit Protection Analogue Current Output
(mA)
Process Connection Connection Operating Voltage
(V)
Max. Resistance Switching Output
(Ω)
Electrical Connection Ambient Temperature
(°C)
Cannot Be Used For Output Function Total Number of Outputs Detection Range
(mm)
Number of Digital Outputs Min. Load Resistance
(Ω)
Output Signal Short-Circuit Protection Tank Pressure
(bar)
Dielectric Constant of the Medium Recommended Media Special Feature Application Media Probe Length
(mm)
Permanent Current Rating of Switching Output DC
(mA)
Max. Power-On Delay Time
(ms)
Surface Characteristics Ra/Rz of the Wetted Parts Overload Protection Measuring Range
(mm)
IO-Link Revision Installation Dimensions
(mm)
Materials (Wetted Parts) Transmission Type Maximum Speed of the Change of Level
(mm/s)

298.66 €

1 4 Days Number of digital outputs: 2---PNP-stainless steel (1.4404 / 316L); PEEK; PEI; FKM< 50--pulsed-G 3/4 external thread-18-30 DC-Connector: 1 x M12; Contacts: gold-plated-20-85See the operating instructions, chapter "Function and features".-2---Switching signal; IO-LinkYes-1-40; (applications subject to the German Federal Water Act : -0.5-10 bar)-water; hydrous media; oils; oil-based mediaGold-plated contactsLiquids28---Yes-1.1suited for installation in existing tuning fork adapters-PEEK; surface characteristics: Ra < 0.8 / Rz 4COM2 (38.4 kBaud)-

Loading...

  1. 1

Basic information

Protection Class III Reverse Polarity Protection Yes Communication Interface IO-Link

This page is Electronic Level Sensor, part number LMT292.
You can find the detail information about specifications and dimensions on part number LMT292.

Variation of this product

Part Number
LK1023
LK1024
LK1222
LMT302
LMT392
LR2050
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Number of Inputs and Outputs Analogue Voltage Output
(V)
Protection Power-On Delay Time
(s)
Electrical Design MAWP (for Applications According to CRN)
(bar)
Materials Current Consumption
(mA)
Application Electrical Connection - Plug Type of Short-Circuit Protection Analogue Current Output
(mA)
Process Connection Connection Operating Voltage
(V)
Max. Resistance Switching Output
(Ω)
Electrical Connection Ambient Temperature
(°C)
Cannot Be Used For Output Function Total Number of Outputs Detection Range
(mm)
Number of Digital Outputs Min. Load Resistance
(Ω)
Output Signal Short-Circuit Protection Tank Pressure
(bar)
Dielectric Constant of the Medium Recommended Media Special Feature Application Media Probe Length
(mm)
Permanent Current Rating of Switching Output DC
(mA)
Max. Power-On Delay Time
(ms)
Surface Characteristics Ra/Rz of the Wetted Parts Overload Protection Measuring Range
(mm)
IO-Link Revision Installation Dimensions
(mm)
Materials (Wetted Parts) Transmission Type Maximum Speed of the Change of Level
(mm/s)

546.78 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV< 50--thermal, pulsed---18-30 DC-Connector: 1 x M120-60extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applicationsnormally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes0.5; (when mounting with mounting accessories: E43001 - E43007. E43019)> 2--hydrous coolants; oils; oil-based media; water; media similar to water472---Yes-1.1-Ø 16PPCOM2 (38.4 kBaud)200

592.34 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV< 50--thermal, pulsed---18-30 DC-Connector: 1 x M12; Contacts: gold-plated0-60extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industrynormally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes0.5; (when mounting with mounting accessories: E43001 - E43007. E43019)> 2-Gold-plated contactshydrous coolants; oils; oil-based media; water; media similar to water728---Yes-1.1-Ø 16PPCOM2 (38.4 kBaud)300

595.80 €

1 4 Days Number of digital outputs: 2-IP 67< 3PNP/NPN-stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); FKM; NBR; PBT; PC; PA; PP; TPV< 50--pulsed---12-30 DC-Connector: 1 x M12; Contacts: gold-plated0-60extremely conductive media; adhering media; granulates; bulk material; acids; alkali; hygienic areas and electroplating applications-2---Switching signal; IO-LinkYes0.5; (unpressurized for applications to WHG (German Federal Water Act))> 2-Gold-plated contactshydrous coolants; oils; oil-based media; water; media similar to water264---Yes-1.1-Ø 16PPCOM2 (38.4 kBaud)100

304.48 €

1 4 Days Number of digital outputs: 2---PNP/NPN-stainless steel (1.4404 / 316L); PEEK; PEI; FKM< 50--pulsed-G 1 external thread-18-30 DC-Connector: 1 x M12; Contacts: gold-plated-20-85See the operating instructions, chapter "Function and features".normally open / normally closed; (parameterisable)2---Switching signal; IO-LinkYes-1-40-water; hydrous media; oils; oil-based media; powderGold-plated contactsLiquids; viscous media; powder38---Yes-1.1suited for installation in existing tuning fork adaptersØ 30 / L = 125.5PEEK; surface characteristics: Ra < 0.8 / Rz 4COM2 (38.4 kBaud)-

304.48 €

1 4 Days Number of digital outputs: 2---PNP-stainless steel (1.4404 / 316L); PEEK; PEI; FKM< 50--pulsed-G 1 external thread-18-30 DC-Connector: 1 x M12; Contacts: gold-plated-20-85See the operating instructions, chapter "Function and features".-2---Switching signal; IO-LinkYes-1-40; (applications subject to the German Federal Water Act : -0.5-10 bar)-water; hydrous media; oils; oil-based mediaGold-plated contactsLiquids38---Yes-1.1suited for installation in existing tuning fork adapters-PEEK; surface characteristics: Ra < 0.8 / Rz 4COM2 (38.4 kBaud)-

757.53 €

1 4 Days Number of digital outputs: 1; Number of analogue outputs: 1-IP 68; IP 69K< 3PNP/NPN16stainless steel (1.4404 / 316L); PEI; PFA; PBT; FKM< 50--pulsed4-20. invertible; (scalable)G 3/4 external thread-18-30 DC---40-80-normally open / normally closed; (parameterisable)2---Switching signal; analogue signal; IO-LinkYes-1-16≥ 1.8; (for media with a dielectric constant of 1.8-5 (e.g. oils), a coaxial pipe is needed for operation)water; hydrous media; oils; oil-based mediaGold-plated contactsLiquids; oil-based media; hydrous media150-2000---Yes-1.1--stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PTFE; FKMCOM2 (38.4 kBaud)-