Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Part Number
|
---|
H3YN-21 AC100-120 |
H3YN-21 AC200-230 |
H3YN-21 DC12 |
H3YN-21 DC24 |
H3YN-41 AC100-120 |
H3YN-41 AC200-230 |
H3YN-41 DC24 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Type | Time specifications (s) | Power Supply Voltage | Rated power supply voltage (V) | Time ranges = N | Contact Configuration | Terminal shape | Operating Modes | Type of Electric Connection | Number of Outputs, Undelayed, Normally Closed Contact | Number of Outputs, Delayed, Normally Open Contact | Number of Outputs, Undelayed, Change-Over Contact | Number of Outputs, Delayed, Change-Over Contact | Number of Outputs, Delayed, Normally Closed Contact | Number of Outputs, Undelayed, Normally Open Contact | Suitable as Remote Control | Function Floating Contact on De-Energization | Function Delay on De-Energization | Remote Operation Possible | With Semiconductor Output | Function Flashing, Starting With Pause, Fixed Time | With Plug-In Socket | Function Pulse Shaping | Function Flashing, Starting With Pulse, Fixed Time | Function Floating Contact on Energization | Function Delay-On Energization | Clock Function, Starting With Pulse, Variable | Clock Function, Starting With Pause, Variable | Function Star-Delta | Pluggable on Auxiliary Contact Block | Outputs, Reversible Delayed/Undelayed | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
66.71 € | 1 | 6 Days | - | 0.1 min – 10 h | AC-dedicated | AC100 to 120 | 4 range | Time Limit 2c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
83.25 € | 10 | 7 Days | - | 0.1 min – 10 h | AC-dedicated | AC200 to 230 | 4 range | Time Limit 2c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
83.25 € | 10 | 7 Days | - | 0.1 min – 10 h | Dedicated to DC | DC12 | 4 range | Time Limit 2c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
83.25 € | 10 | 7 Days | - | 0.1 min – 10 h | Dedicated to DC | DC24 | 4 range | Time Limit 2c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
69.92 € | 1 | 6 Days | - | 0.1 min – 10 h | AC-dedicated | AC100 to 120 | 4 range | Time Limit 4c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
88.00 € | 10 | 7 Days | - | 0.1 min – 10 h | AC-dedicated | AC200 to 230 | 4 range | Time Limit 4c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
88.00 € | 10 | 7 Days | - | 0.1 min – 10 h | Dedicated to DC | DC24 | 4 range | Time Limit 4c | Plug-in terminal | ON-delay, interval, flicker OFF start, or flicker ON start (selectable) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Loading...
Display method | Analog | Output Method | Relay | Representative Standard | CE / UL / CCC / CSA |
---|---|---|---|---|---|
Dimension vertical(mm) | 28 | Dimension width(mm) | 21.5 | Dimension depth(mm) | 52.6 |
Configure
Basic Attributes
Type
Power Supply Voltage
Rated power supply voltage(V)
Time ranges = N
Contact Configuration
Terminal shape
Operating Modes
Type of Electric Connection
Number of Outputs, Undelayed, Normally Closed Contact
Number of Outputs, Delayed, Normally Open Contact
Number of Outputs, Undelayed, Change-Over Contact
Number of Outputs, Delayed, Change-Over Contact
Number of Outputs, Delayed, Normally Closed Contact
Number of Outputs, Undelayed, Normally Open Contact
Suitable as Remote Control
Function Floating Contact on De-Energization
Function Delay on De-Energization
Remote Operation Possible
With Semiconductor Output
Function Flashing, Starting With Pause, Fixed Time
With Plug-In Socket
Function Pulse Shaping
Function Flashing, Starting With Pulse, Fixed Time
Function Floating Contact on Energization
Function Delay-On Energization
Clock Function, Starting With Pulse, Variable
Clock Function, Starting With Pause, Variable
Function Star-Delta
Pluggable on Auxiliary Contact Block
Outputs, Reversible Delayed/Undelayed
Time specifications(s)
Filter by standard shipping days
Optional Attributes