Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | RoHS | Overall Length (m) | Conductor Cross Section (mm2) | Finished outer diameter (mm) | Minimum bending radius while running (mm) | Minimum bending radius when fixed (mm) | Conductor resistance (Ω/km) | Reference allowable current value (30°C) (A) | Other standards | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
713.45 € | 1 | 5 Days | 10 | 21 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2732: Used of UL (AWM) cable allowed | ||
747.42 € | 1 | 5 Days | 10 | 22 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2733: Used of UL (AWM) cable allowed | ||
781.38 € | 1 | 5 Days | 10 | 23 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2734: Used of UL (AWM) cable allowed | ||
815.38 € | 1 | 5 Days | 10 | 24 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2735: Used of UL (AWM) cable allowed | ||
849.35 € | 1 | 5 Days | 10 | 25 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2736: Used of UL (AWM) cable allowed | ||
883.32 € | 1 | 5 Days | 10 | 26 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2737: Used of UL (AWM) cable allowed | ||
917.29 € | 1 | 5 Days | 10 | 27 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2738: Used of UL (AWM) cable allowed | ||
951.26 € | 1 | 5 Days | 10 | 28 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2739: Used of UL (AWM) cable allowed | ||
985.23 € | 1 | 5 Days | 10 | 29 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2740: Used of UL (AWM) cable allowed | ||
1,019.23 € | 1 | 5 Days | 10 | 30 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2741: Used of UL (AWM) cable allowed | ||
1,053.20 € | 1 | 5 Days | 10 | 31 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2742: Used of UL (AWM) cable allowed | ||
1,087.17 € | 1 | 6 Days | 10 | 32 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2743: Used of UL (AWM) cable allowed | ||
1,121.14 € | 1 | 6 Days | 10 | 33 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2744: Used of UL (AWM) cable allowed | ||
1,155.11 € | 1 | 6 Days | 10 | 34 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2745: Used of UL (AWM) cable allowed | ||
1,189.08 € | 1 | 6 Days | 10 | 35 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2746: Used of UL (AWM) cable allowed | ||
1,223.05 € | 1 | 6 Days | 10 | 36 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2747: Used of UL (AWM) cable allowed | ||
1,257.05 € | 1 | 6 Days | 10 | 37 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2748: Used of UL (AWM) cable allowed | ||
1,291.02 € | 1 | 6 Days | 10 | 38 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2749: Used of UL (AWM) cable allowed | ||
1,324.98 € | 1 | 6 Days | 10 | 39 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2750: Used of UL (AWM) cable allowed | ||
1,358.95 € | 1 | 6 Days | 10 | 40 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2751: Used of UL (AWM) cable allowed | ||
1,392.92 € | 1 | 6 Days | 10 | 41 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2752: Used of UL (AWM) cable allowed | ||
1,426.89 € | 1 | 6 Days | 10 | 42 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2753: Used of UL (AWM) cable allowed | ||
1,460.86 € | 1 | 6 Days | 10 | 43 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2754: Used of UL (AWM) cable allowed | ||
1,494.86 € | 1 | 6 Days | 10 | 44 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2755: Used of UL (AWM) cable allowed | ||
1,528.83 € | 1 | 6 Days | 10 | 45 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2756: Used of UL (AWM) cable allowed | ||
1,562.80 € | 1 | 6 Days | 10 | 46 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2757: Used of UL (AWM) cable allowed | ||
1,596.77 € | 1 | 6 Days | 10 | 47 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2758: Used of UL (AWM) cable allowed | ||
1,630.74 € | 1 | 6 Days | 10 | 48 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2759: Used of UL (AWM) cable allowed | ||
1,664.71 € | 1 | 6 Days | 10 | 49 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2760: Used of UL (AWM) cable allowed | ||
1,698.71 € | 1 | 6 Days | 10 | 50 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2761: Used of UL (AWM) cable allowed | ||
1,732.68 € | 1 | 6 Days | 10 | 51 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2762: Used of UL (AWM) cable allowed | ||
1,766.65 € | 1 | 6 Days | 10 | 52 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2763: Used of UL (AWM) cable allowed | ||
1,800.62 € | 1 | 6 Days | 10 | 53 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2764: Used of UL (AWM) cable allowed | ||
1,834.58 € | 1 | 6 Days | 10 | 54 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2765: Used of UL (AWM) cable allowed | ||
1,868.55 € | 1 | 6 Days | 10 | 55 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2766: Used of UL (AWM) cable allowed | ||
1,902.52 € | 1 | 6 Days | 10 | 56 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2767: Used of UL (AWM) cable allowed | ||
1,936.52 € | 1 | 6 Days | 10 | 57 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2768: Used of UL (AWM) cable allowed | ||
1,970.49 € | 1 | 6 Days | 10 | 58 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2769: Used of UL (AWM) cable allowed | ||
2,004.46 € | 1 | 6 Days | 10 | 59 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2770: Used of UL (AWM) cable allowed | ||
2,038.43 € | 1 | 6 Days | 10 | 60 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2771: Used of UL (AWM) cable allowed | ||
2,072.40 € | 1 | 6 Days | 10 | 61 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2772: Used of UL (AWM) cable allowed | ||
2,106.37 € | 1 | 6 Days | 10 | 62 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2773: Used of UL (AWM) cable allowed | ||
2,140.34 € | 1 | 6 Days | 10 | 63 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2774: Used of UL (AWM) cable allowed | ||
2,174.34 € | 1 | 6 Days | 10 | 64 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2775: Used of UL (AWM) cable allowed | ||
2,208.31 € | 1 | 6 Days | 10 | 65 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2776: Used of UL (AWM) cable allowed | ||
2,242.28 € | 1 | 6 Days | 10 | 66 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2777: Used of UL (AWM) cable allowed | ||
2,276.25 € | 1 | 6 Days | 10 | 67 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2778: Used of UL (AWM) cable allowed | ||
2,310.22 € | 1 | 6 Days | 10 | 68 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2779: Used of UL (AWM) cable allowed | ||
2,344.18 € | 1 | 6 Days | 10 | 69 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2780: Used of UL (AWM) cable allowed | ||
2,378.18 € | 1 | 6 Days | 10 | 70 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2781: Used of UL (AWM) cable allowed | ||
2,412.15 € | 1 | 6 Days | 10 | 71 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2782: Used of UL (AWM) cable allowed | ||
2,446.12 € | 1 | 6 Days | 10 | 72 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2783: Used of UL (AWM) cable allowed | ||
2,480.09 € | 1 | 6 Days | 10 | 73 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2784: Used of UL (AWM) cable allowed | ||
2,514.06 € | 1 | 6 Days | 10 | 74 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2785: Used of UL (AWM) cable allowed | ||
2,548.03 € | 1 | 6 Days | 10 | 75 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2786: Used of UL (AWM) cable allowed | ||
2,582.00 € | 1 | 6 Days | 10 | 76 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2787: Used of UL (AWM) cable allowed | ||
2,616.00 € | 1 | 6 Days | 10 | 77 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2788: Used of UL (AWM) cable allowed | ||
2,649.97 € | 1 | 6 Days | 10 | 78 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2789: Used of UL (AWM) cable allowed | ||
2,683.94 € | 1 | 6 Days | 10 | 79 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2790: Used of UL (AWM) cable allowed | ||
2,717.91 € | 1 | 6 Days | 10 | 80 | 50 | 15 | 112.5 | 60 | 0.386 | 202 | ISO class 1 (IPA): Clean room compatible/ CEI: Italian standard/ NFPA 79-2791: Used of UL (AWM) cable allowed |
Loading...
Number Of Cores(Core) | 1 | Rated Voltage | 600/1000V | Shield | Tin plated copper braid |
---|---|---|---|---|---|
Properties | Oil Resistance / Weatherproof | Representative Standard | UL / CE / CSA(c-UL) | Sheath (outer coating) color | Black |
Grounding Wire | N/A | Sheath (outer coating) material | Low adhesiveness TPE admixture | Insulation body materials | TPE admixture |
Free span maximum running speed(m/s) | 10 | Slide maximum running speed(m/s) | 6 | Maximum acceleration(m/s2) | 100 |
Stroke | Up to 400m | Other cable properties | Flame retardant and silicone free | Note 1 | Rated voltage: Uo/U (V) Uo = Voltage between conductor and ground, U = voltage between conductors |
Configure
Basic Attributes
Overall Length(m)
Conductor Cross Section(mm2)
Finished outer diameter(mm)
Minimum bending radius while running(mm)
Minimum bending radius when fixed(mm)
Conductor resistance(Ω/km)
Reference allowable current value (30°C)(A)
Filter by standard shipping days
Optional Attributes