Manufacturer part number: LSHU-E25/1-KL
Brand: EATON
Price: 191.43 €
Delivery time: 35 Days
Rated short-circuit breaking capacity Icn EN 60898 at 400 V: - kA
Rated short-circuit breaking capacity Icn EN 60898 at 230 V: - kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V: - kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V: - kA
Mounting method: DIN rail
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
LSHU-E25/1-KL
Part Number
|
---|
LSHU-E25/1-KL |
Part Number | Related to |
Standard Unit Price
| Minimum order quantity | Volume Discount | Rated short-circuit breaking capacity Icn EN 60898 at 400 V (kA) | Rated short-circuit breaking capacity Icn EN 60898 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (kA) | Mounting method | Voltage type | Built-in depth (mm) | Rated current (A) | Rated voltage (V) | Frequency (Hz) | Release characteristic | Rated insulation voltage Ui (V) | Number of poles | Rated switching capacity (kA) | Construction size (in accordance with DIN 43880) | Current limiting class | Over voltage category | Pollution degree | Rated surge voltage invariability (kV) | Width in number of modular spacings | Degree of protection (IP) | Number of protected poles | Concurrently switching N-neutral | Suitable for flush-mounted installation | Connectable conductor cross section solid-core (mm²) | Connectable conductor cross section multi-wired (mm²) | Ambient temperature during operating (°C) | Additional equipment possible | Number of poles (total) | Rated impulse withstand voltage Uimp (kV) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
191.43 € | 3 | 35 Days | - | - | - | - | DIN rail | - | - | 25 | 230 | 50 | E | 690 | 1 | 25 | 6 | - | 4 | 3 | 6 | - | IP40 | - | false | - | - | - | - | - | - | - |
Loading...
This page is Miniature circuit breaker (MCB), part number LSHU-E25/1-KL.
You can find the detail information about specifications and dimensions on part number LSHU-E25/1-KL.
Configure
Basic Attributes
Rated short-circuit breaking capacity Icn EN 60898 at 400 V(kA)
Rated short-circuit breaking capacity Icn EN 60898 at 230 V(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V(kA)
Voltage type
Built-in depth(mm)
Current limiting class
Width in number of modular spacings
Number of protected poles
Suitable for flush-mounted installation
Connectable conductor cross section solid-core(mm²)
Connectable conductor cross section multi-wired(mm²)
Ambient temperature during operating(°C)
Additional equipment possible
Number of poles (total)
Rated impulse withstand voltage Uimp(kV)
Type
Mounting method
Rated current(A)
Rated voltage(V)
Frequency(Hz)
Release characteristic
Rated insulation voltage Ui(V)
Number of poles
Rated switching capacity(kA)
Construction size (in accordance with DIN 43880)
Over voltage category
Pollution degree
Rated surge voltage invariability(kV)
Degree of protection (IP)
Concurrently switching N-neutral
Filter by standard shipping days
Optional Attributes
Part Number |
---|
AZ-3-C125 |
AZ-3-C63 |
AZ-3-C80 |
LSHU-E25/3-KL |
LSHU-E35/1-KL |
LSHU-E35/3-KL |
Part Number | Related To | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Rated short-circuit breaking capacity Icn EN 60898 at 400 V (kA) | Rated short-circuit breaking capacity Icn EN 60898 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (kA) | Mounting method | Voltage type | Built-in depth (mm) | Rated current (A) | Rated voltage (V) | Frequency (Hz) | Release characteristic | Rated insulation voltage Ui (V) | Number of poles | Rated switching capacity (kA) | Construction size (in accordance with DIN 43880) | Current limiting class | Over voltage category | Pollution degree | Rated surge voltage invariability (kV) | Width in number of modular spacings | Degree of protection (IP) | Number of protected poles | Concurrently switching N-neutral | Suitable for flush-mounted installation | Connectable conductor cross section solid-core (mm²) | Connectable conductor cross section multi-wired (mm²) | Ambient temperature during operating (°C) | Additional equipment possible | Number of poles (total) | Rated impulse withstand voltage Uimp (kV) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
446.05 € | 4 | 4 Days | 0 | 0 | 15 | 15 | - | AC | 75 | 125 | 400 | 50|60 | C | 440 | - | - | - | 3 | 3 | 2 | - | 4.5 | IP20 | 1 | false | false | 2.5|50 | 2.5|50 | -25|55 | true | 3 | 4 | |||
341.38 € | 4 | 4 Days | 0 | 0 | 25 | 25 | - | AC | 75 | 63 | 400 | 50|60 | C | 440 | - | - | - | 3 | 3 | 2 | - | 4.5 | IP20 | 1 | false | false | 2.5|50 | 2.5|50 | -25|55 | true | 3 | 4 | |||
383.84 € | 4 | 4 Days | 0 | 0 | 20 | 20 | - | AC | 75 | 80 | 400 | 50|60 | C | 440 | - | - | - | 3 | 3 | 2 | - | 4.5 | IP20 | 1 | false | false | 2.5|50 | 2.5|50 | -25|55 | true | 3 | 4 | |||
579.31 € | 1 | 4 Days | - | - | - | - | DIN rail | - | - | 25 | 400 | 50 | E | 690 | 3 | 25 | 6 | - | 4 | 3 | 6 | - | IP40 | - | false | - | - | - | - | - | - | - | |||
199.77 € | 3 | 35 Days | - | - | - | - | DIN rail | - | - | 35 | 230 | 50 | E | 690 | 1 | 25 | 6 | - | 4 | 3 | 6 | - | IP40 | - | false | - | - | - | - | - | - | - | |||
- | 597.61 € | 1 | 4 Days | - | - | - | - | DIN rail | - | - | 35 | 400 | 50 | E | 690 | 3 | 25 | 6 | - | 4 | 3 | 6 | - | IP40 | - | false | - | - | - | - | - | - | - |