Miniature circuit breaker (MCB) (FAZ-D10/3-RT)

Miniature circuit breaker (MCB) FAZ-D10/3-RT

Product Details:

Manufacturer part number: FAZ-D10/3-RT

Brand: EATON

Price: 199.00

Delivery time: 3 Days


Technical Data:

Rated short-circuit breaking capacity Icn EN 60898 at 400 V: 0 kA

Rated short-circuit breaking capacity Icn EN 60898 at 230 V: 0 kA

Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V: 15 kA

Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V: 15 kA

Voltage type: AC


Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

FAZ-D10/3-RT

Part Number
FAZ-D10/3-RT
Part NumberRelated to
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Rated short-circuit breaking capacity Icn EN 60898 at 400 V
(kA)
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V
(kA)
Voltage type Built-in depth
(mm)
Rated current
(A)
Frequency
(Hz)
Release characteristic Width in number of modular spacings Number of protected poles Concurrently switching N-neutral Suitable for flush-mounted installation Connectable conductor cross section solid-core
(mm²)
Connectable conductor cross section multi-wired
(mm²)
Ambient temperature during operating
(°C)
Number of poles (total) Rated voltage
(kV)

199.00 €

1 3 Days 001515AC70.51050|60D33falsefalse1|251|25-25|7530.415

Loading...

  1. 1

Basic information

Rated insulation voltage Ui(V) 440 Current limiting class 3 Over voltage category 3
Pollution degree 2 Degree of protection (IP) IP20 Additional equipment possible true
Rated impulse withstand voltage Uimp(kV) 4

This page is Miniature circuit breaker (MCB), part number FAZ-D10/3-RT.
You can find the detail information about specifications and dimensions on part number FAZ-D10/3-RT.

Variation of this product

Part Number
AZ-3-C20
AZ-3-C25
AZ-3-C40
FAZ-D13/2-NA
FAZ-D13/3-RT
FAZ-D15/1-RT
Part NumberRelated ToStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Rated short-circuit breaking capacity Icn EN 60898 at 400 V
(kA)
Rated short-circuit breaking capacity Icn EN 60898 at 230 V
(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V
(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V
(kA)
Voltage type Built-in depth
(mm)
Rated current
(A)
Frequency
(Hz)
Release characteristic Width in number of modular spacings Number of protected poles Concurrently switching N-neutral Suitable for flush-mounted installation Connectable conductor cross section solid-core
(mm²)
Connectable conductor cross section multi-wired
(mm²)
Ambient temperature during operating
(°C)
Number of poles (total) Rated voltage
(kV)

169.75 €

4 38 Days 002525AC752050|60C4.51falsefalse2.5|502.5|50-25|5530.4

193.32 €

4 42 Days 002525AC752550|60C4.51falsefalse2.5|502.5|50-25|5530.4

266.88 €

4 42 Days 002525AC754050|60C4.51falsefalse2.5|502.5|50-25|5530.4

144.29 €

1 11 Days 001515AC70.51350|60D22falsefalse1|251|25-25|7520.415

199.00 €

1 26 Days 001515AC70.51350|60D33falsefalse1|251|25-25|7530.415

60.55 €

2 17 Days 001515AC70.51550|60D11falsefalse1|251|25-25|7510.24