Manufacturer part number: FAZ-D6/3-RT
Brand: EATON
Price: 220.68 €
Delivery time: 37 Days
Rated short-circuit breaking capacity Icn EN 60898 at 400 V: 0 kA
Rated short-circuit breaking capacity Icn EN 60898 at 230 V: 0 kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V: 15 kA
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V: 15 kA
Voltage type: AC
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
FAZ-D6/3-RT
Part Number
|
---|
FAZ-D6/3-RT |
Part Number | Related to |
Standard Unit Price
| Minimum order quantity | Volume Discount | Rated short-circuit breaking capacity Icn EN 60898 at 400 V (kA) | Rated short-circuit breaking capacity Icn EN 60898 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (kA) | Voltage type | Built-in depth (mm) | Rated current (A) | Frequency (Hz) | Release characteristic | Width in number of modular spacings | Number of protected poles | Concurrently switching N-neutral | Suitable for flush-mounted installation | Connectable conductor cross section solid-core (mm²) | Connectable conductor cross section multi-wired (mm²) | Ambient temperature during operating (°C) | Number of poles (total) | Rated voltage (kV) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
220.68 € | 1 | 37 Days | 0 | 0 | 15 | 15 | AC | 70.5 | 6 | 50|60 | D | 3 | 3 | false | false | 1|25 | 1|25 | -25|75 | 3 | 0.415 |
Loading...
Rated insulation voltage Ui(V) | 440 | Current limiting class | 3 | Over voltage category | 3 |
---|---|---|---|---|---|
Pollution degree | 2 | Degree of protection (IP) | IP20 | Additional equipment possible | true |
Rated impulse withstand voltage Uimp(kV) | 4 |
This page is Miniature circuit breaker (MCB), part number FAZ-D6/3-RT.
You can find the detail information about specifications and dimensions on part number FAZ-D6/3-RT.
Configure
Basic Attributes
Type
Rated short-circuit breaking capacity Icn EN 60898 at 400 V(kA)
Rated short-circuit breaking capacity Icn EN 60898 at 230 V(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V(kA)
Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V(kA)
Voltage type
Built-in depth(mm)
Rated current(A)
Frequency(Hz)
Release characteristic
Width in number of modular spacings
Number of protected poles
Concurrently switching N-neutral
Suitable for flush-mounted installation
Connectable conductor cross section solid-core(mm²)
Connectable conductor cross section multi-wired(mm²)
Ambient temperature during operating(°C)
Number of poles (total)
Rated voltage(kV)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
AZ-3-C20 |
AZ-3-C25 |
AZ-3-C40 |
FAZ-D8/3-RT |
FAZ-K20/2 |
FAZ-K50/3 |
Part Number | Related To | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Rated short-circuit breaking capacity Icn EN 60898 at 400 V (kA) | Rated short-circuit breaking capacity Icn EN 60898 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V (kA) | Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V (kA) | Voltage type | Built-in depth (mm) | Rated current (A) | Frequency (Hz) | Release characteristic | Width in number of modular spacings | Number of protected poles | Concurrently switching N-neutral | Suitable for flush-mounted installation | Connectable conductor cross section solid-core (mm²) | Connectable conductor cross section multi-wired (mm²) | Ambient temperature during operating (°C) | Number of poles (total) | Rated voltage (kV) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
169.75 € | 4 | 38 Days | 0 | 0 | 25 | 25 | AC | 75 | 20 | 50|60 | C | 4.5 | 1 | false | false | 2.5|50 | 2.5|50 | -25|55 | 3 | 0.4 | |||
193.32 € | 4 | 42 Days | 0 | 0 | 25 | 25 | AC | 75 | 25 | 50|60 | C | 4.5 | 1 | false | false | 2.5|50 | 2.5|50 | -25|55 | 3 | 0.4 | |||
266.88 € | 4 | 42 Days | 0 | 0 | 25 | 25 | AC | 75 | 40 | 50|60 | C | 4.5 | 1 | false | false | 2.5|50 | 2.5|50 | -25|55 | 3 | 0.4 | |||
220.68 € | 1 | 43 Days | 0 | 0 | 15 | 15 | AC | 70.5 | 8 | 50|60 | D | 3 | 3 | false | false | 1|25 | 1|25 | -25|75 | 3 | 0.415 | |||
94.75 € | 1 | 7 Days | 0 | 0 | 10 | 10 | AC | 70.5 | 20 | 50|60 | K | 2 | 2 | false | false | 1|25 | 1|25 | -25|75 | 2 | 0.4 | |||
267.83 € | 1 | 3 Days | 0 | 0 | 10 | 10 | AC | 70.5 | 50 | 50|60 | K | 3 | 3 | false | false | 1|25 | 1|25 | -25|75 | 3 | 0.4 |