Frequency Inverter [J1000]

Frequency Inverter [J1000]
The basic drive
• V/f controlled drive
• Good torque performance (150% / 3 Hz)
• Double rating ND 120%/1min and HD 150%/1 min
• Overload detection function (150% during 60s)
• Motor thermal function
• Freely configurable V/f curve
• 5 programmable digital input
• 1 programmable digital output
• 1 programmable analog output
• Optional RS-232C/485 communication - Modbus,
• CE, UL, cUL and TUV, RoHS
Ratings
• 200 V Class single-phase 0.1 to 1.5 kW
• 200 V Class three-phase 0.1 to 4.0 kW
• 400 V Class three-phase 0.2 to 4.0 kW

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

Part Number
JZAB0P1BAA
JZAB0P2BAA
JZAB0P4BAA
JZAB0P7BAA
JZAB1P5BAA
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Input voltage class Output Specification Dimension width
(mm)
Dimension depth
(mm)
Max. output at linear load at rated output voltage
(kW)
Max. output at quadratic load at rated output voltage
(kW)
Nominal output current I2N
(A)
Mains voltage
(V)
Max. output voltage
(V)
Integrated breaking resistance

454.53 €

1 3 Days Single-Phase 200 VSingle-Phase68760.120.180.9200 - 240240false

454.53 €

1 3 Days Single-Phase 200 VThree-Phase68760.250.371.9200 - 240240true

501.60 €

1 3 Days Single-Phase 200 VThree-Phase681180.40.553.5200 - 240240true

606.27 €

3 3 Days Single-Phase 200 VThree-Phase108137.51.11.16200 - 240240true

759.33 €

3 3 Days Single-Phase 200 VThree-Phase1081541.52.29.6200 - 240240true

Loading...

  1. 1

Basic information

Dimension height(mm) 128 Mains frequency(Hz) 50/60 Hz Max. output frequency(Hz) 400
Number of HW-interfaces industrial Ethernet 0 Number of HW-interfaces USB 0 Number of HW-interfaces RS-485 0
Number of HW-interfaces RS-422 0 Number of HW-interfaces other 1 Number of interfaces PROFINET 0
Number of HW-interfaces parallel 0 Number of HW-interfaces serial TTY 0 Number of HW-interfaces RS-232 0
Degree of protection NEMA Other, IP20 Relative symmetric net voltage tolerance(%) 10 Relative symmetric net frequency tolerance(%) 5
Supporting protocol for DeviceNet false Supporting protocol for CAN false Supporting protocol for PROFINET IO false
Supporting protocol for TCP/IP false Supporting protocol for Modbus true Supporting protocol for DeviceNet Safety false
Supporting protocol for EtherNet/IP false Supporting protocol for PROFIBUS false Supporting protocol for other bus systems false
4-quadrant operation possible false Application in domestic- and commercial area permitted false With optical interface false
With control element true Type of converter Other With PC connection false
Application in industrial area permitted true Supporting protocol for INTERBUS-Safety false Supporting protocol for KNX false
Supporting protocol for PROFINET CBA false Supporting protocol for SafetyBUS p false Supporting protocol for SUCONET false
Supporting protocol for INTERBUS false Supporting protocol for Data-Highway false Supporting protocol for PROFIsafe false
Supporting protocol for Foundation Fieldbus false Supporting protocol for SERCOS false Supporting protocol for LON false
Supporting protocol for ASI false Supporting protocol for AS-Interface Safety at Work false

Tech Support