No.PartMaterial Surface Treatment
PlungerISO-TC90 Equiv.Gold Plating on Nickel Undercoat
SpringSpring Steel (JIS-SWP)Gold Plating
SleeveBrass*Gold Plating on Nickel Undercoat
CollarBrassNickel Plating
* The material of GNP6 is Phosphor Bronze.

Specifications

Part Number-Tip Shape
GNP12
FNP10N
FNP13
MNP50
-
-
-
-
G
E15
A
G8
Part NumberMounting Pitch (min.)Full StrokeSpring PressureAllowable CurrentResistanceReplacement Cycle (Reference)Mounting Hole for Press-Fitting Dimension (Reference)Unit PriceVolume Discount Rate
Initial2/3 Stroke1 ~ 69 pc (s).70~99100~500
GNP60.8mm3.4mm26gf80gf0.5A50mΩ100,000 times0.48~0.5mm
GNP81.0mm3.4mm23gf80gf1A0.58~0.6mm
GNP121.5mm4.0mm32gf95gf3A300,000 times1.03~1.05mm
FNP103.0mm
(6.0mm)
4.5mm60gf105gf3A80mΩ300,000 timesM2×0.25
FNP10N (with Nut)
FNP10HDN (with Nut)56gf175gf
FNP135.0mm
(7.0mm)
4.0mm60gf100gf3A80mΩ300,000 timesM2.5×0.35
FNP13N (with Nut)
FNP13HDN (with Nut)58gf175gf
FNP22SF3.0mm7.0mm0gf100gf3A80mΩ300,000 times1.98~2.00mm
FNP22150gf
FNP40SF5.0mm17.0mm*0gf220gf3.48~3.50mm
FNP40300gf
FNPS223.0mm8.0mm51gf180gf3A80mΩ300,000 times1.98~2.00mm
FNPS354.0mm8.0mm66gf200gf3.17~3.19mm
MNP507.0mm<9.0mm>7.6mm228gf455gf5A35mΩ300,000 times4.18~4.2mm
Mounting pitches in ( ) are applicable to the contact probes with nut. MNP50 mounting pitches in < > are applicable to G8 tip shape. * Tip shape A is 14.0mm, and TH is 9.5mm.
For orders larger than indicated quantity, please request a quotation.

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
GNP6-C
GNP8-C
GNP12-C
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
RoHSMin. Mounting Pitch
(mm)
Plunger Tip Shape Full Stroke
(mm)
Plunger O.D.
(Ø)
Receptacle O.D. D (Range)
(Ø)
Barrel, Receptacle O.D.
(Ø)
Initial Spring Pressure (Range)
(gf)
Allowable Current
(A)
Receptacle Outermost Diameter
(Ø)
Initial Spring Pressure
(gf)
2/3 Stroke Spring Pressure
(gf)

8.82 €

1 Available 7 Days 100.8[Needle] Needle C3.40.60.01 to 10.520.1 to 30.00.50.652680

8.57 €

1 Available 7 Days 101[Needle] Needle C3.40.80.01 to 10.620.1 to 30.010.82380

6.66 €

1 Available 7 Days 101.5[Needle] Needle C41.21.01 to 1.501.0530.1 to 5031.253295

Loading...

  1. 1

Example of Use

Contact Probes Assembly/Standard:Related Image

Basic information

Type Contact Probes Assemblies Full Stroke (Range)(mm) 3 to 4.5 2/3 Stroke Spring Pressure (Range)(gf) 50.1 to 100
Plunger Material ISO-TC90 Equiv. Plunger Surface Treatment Nickel Plating Base, Gold Plating Plunger Length L1 (Range)(mm) 12.1 to 15
Integrated Probe Type Standard Type Barrel, Receptacle Material Brass Barrel, Receptacle Length L2 (Range)(mm) 5 to 10
Properties Standard Resistance(mΩ) 50 Plunger Length(mm) 13.9
Barrel, Receptacle Length(mm) 8.9