Manufacturer part number: PP7553
Brand: IFM ELECTRONIC
Price: 269.97 €
Delivery time: 4 Days
Number of Inputs and Outputs: Number of digital outputs: 2
Analogue Voltage Output: - V
Min. Pressure Cycles: 100 million
Measuring Range: - mbar
Protection: IP 68; (7 days / 1 m water depth / 0.1 bar)
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
PP7553
Part Number
|
---|
PP7553 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Min. Pressure Cycles | Measuring Range (mbar) | Protection | Min. Bursting Pressure (kPa) | Fill Fluid for Pressure Transfer | Temperature Monitoring | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Measuring Range (psi) | Current Consumption (mA) | Design | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Analogue Current Output (mA) | Process Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Min. Bursting Pressure (mbar) | Min. Bursting Pressure (inH2O) | Min. Bursting Pressure (psi) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | IO-Link Resolution Pressure (mbar) | Surface Characteristics Ra/Rz of the Wetted Parts | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Installation | Display | Materials (Wetted Parts) | Transmission Type | Diaphragm Diameter (mm) | Min. Bursting Pressure (bar) | Measuring Range (inH2O) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
269.97 € | 1 | 4 Days | Number of digital outputs: 2 | - | 100 million | - | IP 68; (7 days / 1 m water depth / 0.1 bar) | - | - | - | PNP | - | 0-2.5 | stainless steel (1.4301 / 304); FKM; EPDM/X; PA | - | < 45 | - | - | For industrial applications | - | pulsed | - | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-36 DC; (communication mode: 18-32) | - | Connector: 1 x M12 | -25-85 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-90 | 2 | - | 170 | - | No (can be retrofitted) | Switching signal; IO-Link; (configurable) | Yes | IO-Link | - | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.0 | - | operation: 2 x LED, green switching status: 2 x LED, yellow Teach function: Yes | stainless steel (1.4305 / 303); ceramics; FKM | COM2 (38.4 kBaud) | - | - | - | - | - |
Loading...
Protection Class | III | Reverse Polarity Protection | Yes |
---|
This page is Electronic Pressure Sensor, part number PP7553.
You can find the detail information about specifications and dimensions on part number PP7553.
Configure
Basic Attributes
Analogue Voltage Output(V)
Measuring Range(mbar)
Min. Bursting Pressure(kPa)
Fill Fluid for Pressure Transfer
Temperature Monitoring
MAWP (for Applications According to CRN)(bar)
Measuring Range(psi)
Design
Measuring Range(kPa)
Conditionally Suitable For
Analogue Current Output(mA)
Measuring Element
IO-Link Resolution Temperature(K)
Process Connection Sealing
Overvoltage Protection
Min. Bursting Pressure(mbar)
Min. Bursting Pressure(inH2O)
Min. Bursting Pressure(psi)
Max. Load(Ω)
Min. Load Resistance(Ω)
Tightening Torque(Nm)
Special Feature
IO-Link Resolution Pressure(mbar)
Surface Characteristics Ra/Rz of the Wetted Parts
No Dead Space
Short-Circuit Proof
Installation
Diaphragm Diameter(mm)
Min. Bursting Pressure(bar)
Measuring Range(inH2O)
MAWP (for Applications According to CRN)(mbar)
Type of Pressure
Number of Inputs and Outputs
Min. Pressure Cycles
Protection
Electrical Design
Measuring Range(bar)
Materials
Current Consumption(mA)
Application
Type of Short-Circuit Protection
Process Connection
Operating Voltage(V)
Electrical Connection
Ambient Temperature(°C)
Output Function
Medium Temperature(°C)
Total Number of Outputs
Switching Frequency DC(Hz)
Restrictor Element Integrated
Output Signal
Short-Circuit Protection
Communication Interface
Application Media
Overload Protection
Min. Insulation Resistance(MΩ)
IO-Link Revision
Display
Materials (Wetted Parts)
Transmission Type
Filter by standard shipping days
Optional Attributes
Part Number |
---|
PA3023 |
PA3024 |
PA3026 |
PP7554 |
PP7556 |
PPA020 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Analogue Voltage Output (V) | Min. Pressure Cycles | Measuring Range (mbar) | Protection | Min. Bursting Pressure (kPa) | Fill Fluid for Pressure Transfer | Temperature Monitoring | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Measuring Range (psi) | Current Consumption (mA) | Design | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Analogue Current Output (mA) | Process Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Min. Bursting Pressure (mbar) | Min. Bursting Pressure (inH2O) | Min. Bursting Pressure (psi) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | IO-Link Resolution Pressure (mbar) | Surface Characteristics Ra/Rz of the Wetted Parts | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Installation | Display | Materials (Wetted Parts) | Transmission Type | Diaphragm Diameter (mm) | Min. Bursting Pressure (bar) | Measuring Range (inH2O) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-10 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-2.5 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
269.97 € | 1 | 4 Days | Number of digital outputs: 2 | - | 100 million | - | IP 68; (7 days / 1 m water depth / 0.1 bar) | - | - | - | PNP | - | -1-10 | stainless steel (1.4301 / 304); FKM; EPDM/X; PA | - | < 45 | - | - | For industrial applications | - | pulsed | - | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-36 DC; (communication mode: 18-32) | - | Connector: 1 x M12 | -25-85 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-90 | 2 | - | 170 | - | No (can be retrofitted) | Switching signal; IO-Link; (configurable) | Yes | IO-Link | - | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.0 | - | operation: 2 x LED, green switching status: 2 x LED, yellow Teach function: Yes | stainless steel (1.4305 / 303); ceramics; FKM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
269.97 € | 1 | 4 Days | Number of digital outputs: 2 | - | 100 million | - | IP 68; (7 days / 1 m water depth / 0.1 bar) | - | - | - | PNP | - | 0-2.5 | stainless steel (1.4301 / 304); FKM; EPDM/X; PA | - | < 45 | - | - | For industrial applications | - | pulsed | - | threaded connection G 1/4 external thread internal thread:M5 | - | 9.6-36 DC; (communication mode: 18-32) | - | Connector: 1 x M12 | -25-85 | - | - | - | - | - | normally open / normally closed; (parameterisable) | -25-90 | 2 | - | 170 | - | No (can be retrofitted) | Switching signal; IO-Link; (configurable) | Yes | IO-Link | - | - | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | 1.0 | - | operation: 2 x LED, green switching status: 2 x LED, yellow Teach function: Yes | stainless steel (1.4305 / 303); ceramics; FKM | COM2 (38.4 kBaud) | - | - | - | - | - | ||
524.20 € | 1 | 12 Days | - | - | 100 million | - | IP 67 | - | - | - | AS-i | - | 0-400 | stainless steel (1.4301 / 304); PA | - | < 25 | Analogue value (16 bit value incl. sign) | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | - | threaded connection G 1/4 internal thread | - | 18-31.6 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-70 | - | - | - | - | - | - | -25-80 | - | - | - | - | Yes | - | - | - | - | Gold-plated contacts | Liquids | - | - | Yes | - | 100; (500 V DC) | - | - | - | operation: LED, green failure: LED, red | stainless steel (1.4305 / 303); ceramics; FKM | - | - | 1000 | - | - | relative pressure |