Manufacturer part number: PY9951
Brand: IFM ELECTRONIC
Price: 707.34 €
Delivery time: 12 Days
Number of Inputs and Outputs: Number of digital outputs: 1; Number of analogue outputs: 1
Analogue Voltage Output: 0-10 V
Min. Pressure Cycles: 100 million
Measuring Range: - mbar
Protection: IP 67
Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
PY9951
Part Number
|
---|
PY9951 |
Part Number |
Standard Unit Price
| Minimum order quantity | Volume Discount | Number of Inputs and Outputs | Analogue Voltage Output (V) | Min. Pressure Cycles | Measuring Range (mbar) | Protection | Min. Bursting Pressure (kPa) | Fill Fluid for Pressure Transfer | Temperature Monitoring | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Measuring Range (psi) | Current Consumption (mA) | Design | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Analogue Current Output (mA) | Process Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Min. Bursting Pressure (mbar) | Min. Bursting Pressure (inH2O) | Min. Bursting Pressure (psi) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | IO-Link Resolution Pressure (mbar) | Surface Characteristics Ra/Rz of the Wetted Parts | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Installation | Display | Materials (Wetted Parts) | Transmission Type | Diaphragm Diameter (mm) | Min. Bursting Pressure (bar) | Measuring Range (inH2O) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
707.34 € | 1 | 12 Days | Number of digital outputs: 1; Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 67 | - | - | - | PNP | - | 0-250 | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM | - | < 50 | - | - | - | - | pulsed | 4-20 | threaded connection G 3/4 external thread | - | 18-36 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -20-80 | - | Yes; (< 40 V) | - | - | - | normally open / normally closed; (parameterisable) | -25-80 | 2 | (Ub - 10 V) / 20 mA | < 170 | 2000 | - | Switching signal; analogue signal; (configurable) | Yes | - | - | Gold-plated contacts | viscous media and liquids with suspended particles | - | - | - | - | 100; (500 V DC) | - | - | - | Display unit: 3 x LED, green switching status: LED, yellow function display: alphanumeric display, 4-digit measured values: alphanumeric display, 4-digit | stainless steel (1.4404 / 316L); ceramics; FKM | - | - | - | - | - | - |
Loading...
Protection Class | III | Reverse Polarity Protection | Yes |
---|
This page is Electronic Pressure Sensor, part number PY9951.
You can find the detail information about specifications and dimensions on part number PY9951.
Configure
Basic Attributes
Measuring Range(mbar)
Min. Bursting Pressure(kPa)
Fill Fluid for Pressure Transfer
Temperature Monitoring
MAWP (for Applications According to CRN)(bar)
Measuring Range(psi)
Design
Measuring Range(kPa)
Application
Conditionally Suitable For
Measuring Element
IO-Link Resolution Temperature(K)
Process Connection Sealing
Min. Bursting Pressure(mbar)
Min. Bursting Pressure(inH2O)
Min. Bursting Pressure(psi)
Restrictor Element Integrated
Communication Interface
Tightening Torque(Nm)
IO-Link Resolution Pressure(mbar)
Surface Characteristics Ra/Rz of the Wetted Parts
Overload Protection
No Dead Space
Short-Circuit Proof
IO-Link Revision
Installation
Transmission Type
Diaphragm Diameter(mm)
Min. Bursting Pressure(bar)
Measuring Range(inH2O)
MAWP (for Applications According to CRN)(mbar)
Type of Pressure
Number of Inputs and Outputs
Analogue Voltage Output(V)
Min. Pressure Cycles
Protection
Electrical Design
Measuring Range(bar)
Materials
Current Consumption(mA)
Type of Short-Circuit Protection
Analogue Current Output(mA)
Process Connection
Operating Voltage(V)
Electrical Connection
Ambient Temperature(°C)
Overvoltage Protection
Output Function
Medium Temperature(°C)
Total Number of Outputs
Max. Load(Ω)
Switching Frequency DC(Hz)
Min. Load Resistance(Ω)
Output Signal
Short-Circuit Protection
Special Feature
Application Media
Min. Insulation Resistance(MΩ)
Display
Materials (Wetted Parts)
Filter by standard shipping days
Optional Attributes
Part Number |
---|
PA3021 |
PA3022 |
PA3023 |
PA3024 |
PA3026 |
PY9964 |
Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Standard Shipping Days ? | Number of Inputs and Outputs | Analogue Voltage Output (V) | Min. Pressure Cycles | Measuring Range (mbar) | Protection | Min. Bursting Pressure (kPa) | Fill Fluid for Pressure Transfer | Temperature Monitoring | Electrical Design | MAWP (for Applications According to CRN) (bar) | Measuring Range (bar) | Materials | Measuring Range (psi) | Current Consumption (mA) | Design | Measuring Range (kPa) | Application | Conditionally Suitable For | Type of Short-Circuit Protection | Analogue Current Output (mA) | Process Connection | Measuring Element | Operating Voltage (V) | IO-Link Resolution Temperature (K) | Electrical Connection | Ambient Temperature (°C) | Process Connection Sealing | Overvoltage Protection | Min. Bursting Pressure (mbar) | Min. Bursting Pressure (inH2O) | Min. Bursting Pressure (psi) | Output Function | Medium Temperature (°C) | Total Number of Outputs | Max. Load (Ω) | Switching Frequency DC (Hz) | Min. Load Resistance (Ω) | Restrictor Element Integrated | Output Signal | Short-Circuit Protection | Communication Interface | Tightening Torque (Nm) | Special Feature | Application Media | IO-Link Resolution Pressure (mbar) | Surface Characteristics Ra/Rz of the Wetted Parts | Overload Protection | No Dead Space | Min. Insulation Resistance (MΩ) | Short-Circuit Proof | IO-Link Revision | Installation | Display | Materials (Wetted Parts) | Transmission Type | Diaphragm Diameter (mm) | Min. Bursting Pressure (bar) | Measuring Range (inH2O) | MAWP (for Applications According to CRN) (mbar) | Type of Pressure |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-250 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | Yes | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 68; IP 69K | - | - | - | - | - | 0-100 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | use in gases at pressures > 25 bar only on request | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-25 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-10 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
304.32 € | 1 | 4 Days | Number of analogue outputs: 1 | - | 100 million | - | IP 65 | - | - | - | - | - | 0-2.5 | stainless steel (1.4404 / 316L); FKM; PA; EPDM/X | - | - | - | - | For industrial applications | - | - | 4-20 | threaded connection G 1/4 internal thread | - | 9.6-32 DC | - | Connector: 1 x M12; Contacts: gold-plated | -25-80 | - | - | - | - | - | - | -25-90; (on request: -40-90 °C) | 1 | 720; (Ub = 24 V; (Ub - 9.6 V) / 20 mA) | - | - | No (can be retrofitted) | Analogue signal | - | - | - | Gold-plated contacts | Liquids and gases | - | - | Yes | - | 100; (500 V DC) | - | - | - | - | stainless steel (1.4305 / 303); ceramics; FKM | - | - | - | - | - | - | ||
655.69 € | 1 | 12 Days | Number of digital outputs: 1; Number of analogue outputs: 1 | 0-10 | 100 million | - | IP 67 | - | - | - | PNP | - | -1-10 | stainless steel (1.4301 / 304); stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE | - | < 50 | - | - | For industrial applications | - | pulsed | 4-20 | threaded connection G 3/4 external thread | - | 18-36 DC; (according to EN 50178 SELV/PELV) | - | Connector: 1 x M12; Contacts: gold-plated | -15-80 | - | Yes; (< 40 V) | - | - | - | normally open / normally closed; (parameterisable) | -15-80 | 2 | (Ub - 10 V) / 20 mA | < 170 | 2000 | - | Switching signal; analogue signal; (configurable) | Yes | - | - | Gold-plated contacts | Liquids and gases | - | - | - | - | 100; (500 V DC) | - | - | - | Display unit: 3 x LED, green switching status: LED, yellow function display: alphanumeric display, 4-digit measured values: alphanumeric display, 4-digit | stainless steel (1.4404 / 316L); ceramics (99.9 % Al2O3); FKM | - | - | - | - | - | - |