DOL starter (MSC-D-2,5-M7(24VDC))

DOL starter MSC-D-2,5-M7(24VDC)

Product Details:

Manufacturer part number: MSC-D-2,5-M7(24VDC)

Brand: EATON

Price: 167.29

Delivery time: 3 Days


Technical Data:

Rated conditional short-circuit current, type 2, 400 V: 50000 A

Rated conditional short-circuit current, type 2, 230 V: 50000 A

Number of auxiliary contacts as normally open contact: 1

Number of auxiliary contacts as normally closed contact: 0

Height: 180 mm


  • New Product

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

MSC-D-2,5-M7(24VDC)

Part Number
MSC-D-2,​5-M7(24VDC)
Part NumberRelated to
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
Rated conditional short-circuit current, type 2, 400 V
(A)
Rated conditional short-circuit current, type 2, 230 V
(A)
Number of auxiliary contacts as normally open contact Number of auxiliary contacts as normally closed contact Height
(mm)
Depth
(mm)
Rated operation power at AC-3, 400 V
(kW)
Rated operation current Ie
(A)
Overload release current setting
(A)
Supporting protocol for other bus systems Rated control supply voltage Us at AC 50HZ
(V)
Rated control supply voltage Us at AC 60HZ
(V)
Rated control supply voltage Us at DC
(V)
Degree of protection (IP) Release class Voltage type for actuating Rated operation power at AC-3, 230 V, 3-phase
(kW)
Rated power, 460 V, 60 Hz, 3-phase
(kW)
Rated operation current at AC-3, 400 V
(A)
Coordination class according to IEC 60947-4-3

167.29 €

1 3 Days 500005000010180950.751.91.6|2.5false0|00|024|24IP20CLASS 10DC0.3702.5Class 2

Loading...

  1. 1

Basic information

Supporting protocol for AS-Interface Safety at Work false Rated conditional short-circuit current, type 1, 480 Y/277 V(A) 0 Rated conditional short-circuit current, type 1, 600 Y/347 V(A) 0
Width(mm) 45 With transformer false Number of command positions 0
Suitable for emergency stop false Number of indicator lights 0 Supporting protocol for LON false
Supporting protocol for TCP/IP false Supporting protocol for ASI false Supporting protocol for PROFIBUS false
Supporting protocol for CAN false Supporting protocol for INTERBUS false Supporting protocol for MODBUS false
Supporting protocol for Data-Highway false Supporting protocol for DeviceNet false Supporting protocol for SUCONET false
External reset possible false Rail mounting possible true Supporting protocol for SERCOS false
Supporting protocol for INTERBUS-Safety false With short-circuit release true With fuse false
Type of electrical connection of main circuit Screw connection Supporting protocol for DeviceNet Safety false Supporting protocol for EtherNet/IP false
Supporting protocol for Foundation Fieldbus false Supporting protocol for PROFINET CBA false Supporting protocol for PROFINET IO false
Supporting protocol for PROFIsafe false Supporting protocol for SafetyBUS p false Kind of motor starter Direct starter
Rated power, 575 V, 60 Hz, 3-phase(kW) 0 Ambient temperature, upper operating limit(°C) 60 Temperature compensated overload protection true
Degree of protection (NEMA) Other Type of electrical connection for auxiliary- and control current circuit Screw connection

This page is DOL starter, part number MSC-D-2,5-M7(24VDC).
You can find the detail information about specifications and dimensions on part number MSC-D-2,5-M7(24VDC).

Variation of this product

Part Number
MSC-D-0,​4-M7(24VDC)
MSC-D-0,​63-M7(230V50HZ)
MSC-D-0,​63-M7(24VDC)
MSC-D-2,​5-M7(24VDC)/BBA
MSC-D-25-M25(230V50HZ)
MSC-D-25-M25(230V50HZ)/BBA
Part NumberRelated ToStandard Unit PriceMinimum order quantityVolume DiscountStandard
Shipping Days
?
Rated conditional short-circuit current, type 2, 400 V
(A)
Rated conditional short-circuit current, type 2, 230 V
(A)
Number of auxiliary contacts as normally open contact Number of auxiliary contacts as normally closed contact Height
(mm)
Depth
(mm)
Rated operation power at AC-3, 400 V
(kW)
Rated operation current Ie
(A)
Overload release current setting
(A)
Supporting protocol for other bus systems Rated control supply voltage Us at AC 50HZ
(V)
Rated control supply voltage Us at AC 60HZ
(V)
Rated control supply voltage Us at DC
(V)
Degree of protection (IP) Release class Voltage type for actuating Rated operation power at AC-3, 230 V, 3-phase
(kW)
Rated power, 460 V, 60 Hz, 3-phase
(kW)
Rated operation current at AC-3, 400 V
(A)
Coordination class according to IEC 60947-4-3

153.00 €

1 5 Days 500005000010180950.090.310.25|0.4false0|00|024|24IP20CLASS 10DC0.0600.4Class 2

147.70 €

1 5 Days 500005000010180950.180.60.4|0.63false230|2300|00|0IP20CLASS 10AC0.0900.63Class 2

154.93 €

1 3 Days 500005000010180950.180.60.4|0.63false0|00|024|24IP20CLASS 10DC0.0900.63Class 2

219.90 €

1 21 Days 5000050000102001540.751.91.6|2.5false0|00|024|24IP20CLASS 10DC0.3702.5Class 2

267.51 €

1 5 Days 500005000010228123.41121.720|25false230|2300|00|0IP00CLASS 10AC5.5025Class 2

328.55 €

1 3 Days 5000050000102001561121.720|25false230|2300|00|0IP00CLASS 10AC5.5025Class 2

Tech Support