Benefits · The “LD” (Long Distance) variant allows modules to be connected even further away and saves additional AS-i power supplies · Red cable for transmission of 230 V AC auxiliary power, suitable for power applications · Available in 3 different sheath designs (rubber, TPE, PVC) · The “PVC A” version is certified for the North American market · Yellow cable for simultaneous power and data supply via separate cores for complete data exchange and reduced wiring effort · The “TPE” version with oil-resistant outer sheath is especially suitable for wet areas in conjunction with water-soluble cooling lubricants · Black cable for transmission of 30 V DC auxiliary power · The “G” variant is halogen free · Reverse polarity protection technology thanks to geometrically coded cable
Application · Sensor-/actuator wiring · For fixed installation as well as occasional flexing at free, non-continuously recurring movement without tensile load · Communication at sensor/actuator level · The TPE version has an oil-resistant outer sheath It is suitable for wet areas, in particular in conjunction with water-soluble cooling lubricants
Benefits · The “LD” (Long Distance) variant allows modules to be connected even further away and saves additional AS-i power supplies · High oil-resistance · Particularly oil-resistant and flame retardant · UL certification according to technical data enables the product to be used on the North American market · The new BUS ASI LD 2 x 25 (Long Distance) allows even modules located further away to be connected AS-I power supplies can be reduced The BUS ASI LD is downwards-compatible with version 15 · Yellow cable for simultaneous power and data supply via separate cores for complete data exchange and reduced wiring effort · For highly flexible applications (power chains, moving machine parts) · Black cable for transmission of 30 V DC auxiliary power · Reverse polarity protection technology thanks to geometrically coded cable
Application · The cable design allows flexible, continuously flexing use in moving machine parts and in the cable chain · Can be used universally on machine interfaces for many applications in data and signal transmission · Sensor-/actuator wiring · Suitable for many applications, depending on the sheath material · Communication at sensor/actuator level
Benefits · For serial transmission of safety-oriented data
Application · UNITRONIC BUS SAEFTY - fixed InstallationUNITRONIC BUS SAEFTY FD P - highly flexible applications · For systems such as SafetyBUS p®, based on the well-known CAN bus system
The LAN cable can be used in places with a high density of terminal devices, for example in administrative buildings. It transmits the digital and analogue signals.Data cable for Category 7/ class F - verified up to 1000 MHzCPR: Article number choice under www.lappkabel.com/cpr